background image

6 of 9

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P2XRO-E

Technical Data Sheet

Defrost 

Termination 

Thermostat

Refrigeration 

Thermostat

Dark Blue

3

To 
Condensing 
Unit

}

Light Blue

2

1, 2 & 3 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

 

 
 

4 ft 
6 ft 
8 ft 

12 ft

12 ft

5

5

4

4

4

5

5

5

5

5

5

Optional 

Two Row 

Canopy

Optional 

Three Row 

Canopy

Connector

5

BL

W

BL

W

G

R

BL

W

B

R

R

R

BL

BL

R

BL

R

R

R

BL

BL

R

BL

R

R

R

B

B

Orange or Tan Band

 

 

                                      3 Row Canopy

5

4

5

5

Connector

W

B

BL

BL

R

BL

R

R

R

B

4 ft

6 ft or 8 ft

12 ft

4 ft

6 ft or 8 ft

12 ft

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Fan Wiring
Offtime Defrost

Light Circuits

Summary of Contents for P2XRO-E

Page 1: ...andard Fan Assembly 1 0392457 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 Item Part Description Wiring Item B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744 C Optional Adjustable Refrigeration Thermostat 3 LAMPS BALLASTS LED FIXTURES AND POWER SUPPLY D Ballast E...

Page 2: ...50 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to center of stub up area 38 1 2 978 38 1 2 978 38 1 2 978 38 1 2 978 ...

Page 3: ...hr ft per shelf row for fluorescent lamps DEFROST DATA P2XRO E Frequency hr 8 Defrost Water lb ft day 6 15 based on case configuration and product loading OFFTIME P2XRO E Temp Term F 48 F Failsafe Minutes 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control P2XRO E CI CO 17 7 F Indoor Unit Only Pressure ...

Page 4: ... 60Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 ...

Page 5: ...l Display Area 3 Sq Ft Ft 3 92 ft2 ft 1 19 m2 m Shelf Area 4 Sq Ft Ft 6 59 ft2 ft 2 01 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Length ft m 4 Shelf s...

Page 6: ...al Two Row Canopy Optional Three Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser mu...

Page 7: ...L FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Two Rows of Shelves 4 ft case Connector 5 4 5 B W Connector 6 ft or 8 ft case 12 ft case R R W BL BL R B BL BL R 5 4 5 B W R R W BL BL R B BL BL R Optional Shelf Lighting Fluorescent Fixtures ...

Page 8: ...L 7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves R R B Optional Shelf Lighting LED Fixture...

Page 9: ...BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shelf Harness and LED Light Circuits for 3...