background image

P/N 0481571_A

D

C

E

A

E

C

B

F

G

E

P4XRO-E

Technical Data Sheet 

P/N 0481571_A

NSF

®

Certified

March  2008

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES

4 Ft, 8 Ft & 12 Ft

A.

12W Standard

Fan Assembly 

(1)

0047000

Fan Motor, Evaporator
(MO.4410103)

0461805

Fan Blade (FB.4780446)

12W Energy Efficient

Fan Assembly 

(1)

0477655

Fan Motor, Evaporator 
(MO.4410546)

0461805

Fan Blade (FB.4780446)

6 Ft Only 

A.

7W Standard 

Fan Assembly  

(1)

0058698

Fan Motor, Evaporator
(MO.4410102)

0142780

Fan Blade (FB.0142780)

7W Energy Efficient

Fan Assembly 

(1)

0477654

Fan Motor, Evaporator
(MO.4410545)

0142780

Fan Blade (FB.0142780)

Item Part #

Description

Wiring Item #

T

HERMOSTATS

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat
(CT.0411744)

C. Optional Adjustable Refrigeration Thermostat (3)

L

AMPS

. B

ALLASTS

, LED F

IXTURES AND

P

OWER

S

UPPLY

D. Ballast, Electronic

(4)

0480130

2 lamps (BA.4481676)

0480131

3 lamps (BA.4481654)

0480132

4 lamps (BA.4481677)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

F. 0501213

Power Supply (EP.4481861)

(6)

G.

LED Fixture

(7)

Replace with like fixtures

©2008 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

Note:  Revision A changes ballast (

Page 1

); adds optional LED lighting (

Pages 1, 3, 4, 8

); adds capacity and weight (

Page 5

).

Summary of Contents for P4XRO-E

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part D...

Page 2: ...750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Fie...

Page 3: ...48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb P4XRO E 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types Actual refrigerant ch...

Page 4: ...ection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additio...

Page 5: ...isplay Area 3 Sq Ft Ft 4 88 ft2 ft 1 49 m2 m Shelf Area 4 Sq Ft Ft 8 09 ft2 ft 2 47 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerate...

Page 6: ...l Two Row Canopy Optional Three Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R B 4 ft 6...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...