background image

Electrical Data

4 ft

6 ft

8 ft

12 ft

Number of Fans—12W

2

4

6

Number of Fans—7W

4

Amperes

Watts

4 ft

6 ft

8 ft

12 ft

4 ft

6 ft

8 ft

12 ft

Evaporator Fan

120V

60Hz

Standard

1.30

2.00

2.60

3.90

100

156

200

300

120V

50Hz

Standard

1.50

2.20

3.00

4.50

114

168

228

342

230V

60Hz

Export

0.66

1.00

1.32

1.98

100

156

200

300

230V

50Hz

Export

0.76

1.12

1.52

2.28

114

168

228

342

120V

60Hz

Energy Efficient

0.60

0.76

1.20

1.80

36

56

72

108

230V

60Hz

Energy Efficient

0.30

0.40

0.60

0.90

36

56

72

108

Minimum Circuit Ampacity

120V

60Hz

Standard

1.50

2.20

2.80

4.10

120V

50Hz

Standard

1.70

2.40

3.20

4.70

230V

60Hz

Export

0.86

1.20

1.52

2.18

230V

50Hz

Export

0.96

1.32

1.72

2.48

120V

60Hz

Energy Efficient

0.80

0.96

1.40

2.00

230V

60Hz

Energy Efficient

0.50

0.60

0.80

1.10

Maximum Over Current Protection 120V

20

20

20

20

Maximum Over Current Protection 230V

15

15

15

15

Standard Lighting (T-8 fluorescent)

1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Optional Lighting (T-8 fluorescent)

Additional 1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Additional 2 Row Canopy

0.51

1.02

1.02

1.54

59

118

118

170

Additional 3 Row Canopy

0.77

1.53

1.53

2.31

89

177

177

255

1 Row Rail Light

0.26

0.51

0.51

0.77

30

59

59

85

Optional Shelf Lighting (T-8 fluorescent)

3 Rows of Shelves

0.77

1.53

1.53

2.31

59

177

177

255

4 Rows of Shelves

1.02

2.04

2.04

3.08

118

236

236

340

5 Rows of Shelves

1.28

2.55

2.55

3.85

148

295

295

425

Optional Always*Bright LED Lighting

3 Rows of Shelves

0.38

0.53

0.74

1.11

45

63

89

133

4 Rows of Shelves

0.47

0.68

0.93

1.40

56

82

112

168

5 Rows of Shelves

0.57

0.83

1.13

1.69

68

99

136

203

120V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting

230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52

4 of 8

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P4XRO-E

Technical Data Sheet

Impact  

Excel

P4XRO-E

Produce

Summary of Contents for P4XRO-E

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part D...

Page 2: ...750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Fie...

Page 3: ...48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb P4XRO E 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types Actual refrigerant ch...

Page 4: ...ection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additio...

Page 5: ...isplay Area 3 Sq Ft Ft 4 88 ft2 ft 1 49 m2 m Shelf Area 4 Sq Ft Ft 8 09 ft2 ft 2 47 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerate...

Page 6: ...l Two Row Canopy Optional Three Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R B 4 ft 6...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...