background image

PWR 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

2 of 4

Front

PWR-8E

Waste Outlet
& Water Seal

H

A

Base Rail

Refrigeration Outlet

(See Note***)

Access Area

(See Note*)

7

/

8

(149)

9

(230)

1

/

2

(89)

81 

1

/

2

(2070)

98 

1

/

2

(2502)

C

L

B

C

G

(See Note**)

F

E

D

Engineering

Plan Views

98 Inch

Wide Island

Bulk Produce

07-2003

Dimensions are shown as inches & (mm).

General

8 Ft

12 Ft

(A)

Case length

96 

3

/

8

(2448) 144 

1

/

2

(3670)

Maximum outside dimension of case back to front (includes bumper)

98 

1

/

2

(2502)

98 

1

/

2

(2502)

Front of splashguard to outside edge of base rail

7

/

8

(149)

7

/

8

(149)

Back of case to outside edge of front base rail

81 

1

/

2

(2070)

81 

1

/

2

(2070)

Front of case to outside ede of front base rail

17 (432)

17 (432)

Width of base rail

1

/

8

(54)

1

/

8

(54)

Stub up area between front base rail and splashguard

7

/

8

(124)

7

/

8

(124)

Electrical Service 

(B)

Righthand end of case to center of farthest knockout

95 

3

/

8

(2423) 143 

1

/

2

(3645)

Length of electrical raceway

34 

5

/

8

(878)

34 

5

/

8

(878)

*Note:

Electrical field wiring connection point.

Waste Outlet

(C)

Righthand end of case to center of waste outlet

72 

1

/

4

(1835)

72 

1

/

4

(1835)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

4 (102)

Center of waste outlet to outside edge of front base rail

1

/

2

(89)

1

/

2

(89)

** 

Note

:

Field installed water seal outlets, tees, and connectors are shipped with case

Drip Pipe Outlet
(D)

Left end of case to center of drip pipe outlet

19 

1

/

2

(495)

68 

1

/

2

(1740)

(E)

Center of waste outlet to center of drip pipe outlet

51 

7

/

8

(1318)

3

/

4

(95)

(F)

Front of case to center of drip pipe outlet

25 

7

/

8

(657)

24 

7

/

8

(632)

Outside diameter of drip pipe lines

1

/

2

(38)

1

/

2

(38)

*

**

Note

:

Field drip pipe connection point.

Refrigeration Outlet

(G)

Righthand end of case to center of refrigeration outlet

9 (230)

9 (230)

Center of refrigeration outlet to outside edge
of front base rail

1

/

2

(89)

1

/

2

(89)

Summary of Contents for PWR

Page 1: ...cription Wiring Item FAN ASSEMBLIES AND THERMOSTATS A 0378349 Fan Motor Evaporator 1 0142780 Fan Blade Embossing toward motor We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to corresponding changes improvements additions or replacements for equipment previously sold or shipped ...

Page 2: ...Electrical Service B Righthand end of case to center of farthest knockout 95 3 8 2423 143 1 2 3645 Length of electrical raceway 34 5 8 878 34 5 8 878 Note Electrical field wiring connection point Waste Outlet C Righthand end of case to center of waste outlet 72 1 4 1835 72 1 4 1835 Water Seal Edge of water seal to center of waste outlet 4 102 4 102 Center of waste outlet to outside edge of front b...

Page 3: ...up Control PWR 8 12E CI CO 17 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 11 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb PWR 8 12E 8 ft 2 8 12 ft 4 3 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Ad...

Page 4: ...10 Min Circuit Ampacity With Standard Fans 120V 60Hz 1 74 2 51 With Energy Efficient Fans 120V 60Hz 0 96 1 34 With Export Fans 230V 50 Hz 1 14 1 61 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting Optional Lighting Optional Shelf Lighting None None None Fan Wiring Offtime Defrost 120V POWER 120V NEUTRAL 1 2 3 Fans 120V NEUTRAL BROWN BAND 120V ...

Reviews: