background image

P/N 0417992A

3 of 4

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Impact  

PWR

Produce

Wide Island, 1 Display Level

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H.

PWR

8,12E

Discharge Air (°F)

34

Evaporator(°F)

24

Unit Sizing (°F)

22

Btu/hr/ft*

PWR

8,12E

Parallel

1255

Conventional

1385

*

For all refrigeration equipment other than

Hussmann, use conventional Btu values.

DEFROST DATA

PWR

8,12E

Frequency (hr)

6

Defrost Water (lb/ft/day)

8

(± 15% 

based on case configuration and

product loading).

O

FFTIME

PWR

8,12E

Temp Term (°F)

N/A

Failsafe (minutes)

45

CONVENTIONAL  CONTROLS

Low Pressure Backup Control

PWR

8,12E

CI/CO**

17°/ 7° F

Indoor Unit Only, Pressure Defrost

Termination**

48° F

**Use a Temperature Pressure Chart to

determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lb)***

PWR

8,12E

8 ft 

2.8

12 ft 

4.3

***

This is an average for all refrigerant types.

Actual refrigerant charge may vary by

approximately half a pound.

Length Added to Lineup by

Each End/Partition (in.)

1

/

2

NSF Certification

These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF

®

) Standard #7 requirements.

LC

Fr

ont

of

Case

COIL

Optional

Rack

Positions

PWR

 

Electrical

44

(1118)

30 

3

/

8

(772)

39 

7

/

8

(1013)

(152)

15 

1

/

2

(394)

39 

7

/

8

(1013)

12 

3

/

8

(314)

1

/

(114)

FA

N

COIL

81 

1

/

(2070)

98 

1

/

(2502)

17

(432)

7

/

8

(149)

9

(229)

1

/

(89)

25 

1

/

2

(648)

17 

3

/

8

(441)

Dimensions are shown as inches & (mm).

Summary of Contents for PWR

Page 1: ...cription Wiring Item FAN ASSEMBLIES AND THERMOSTATS A 0378349 Fan Motor Evaporator 1 0142780 Fan Blade Embossing toward motor We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to corresponding changes improvements additions or replacements for equipment previously sold or shipped ...

Page 2: ...Electrical Service B Righthand end of case to center of farthest knockout 95 3 8 2423 143 1 2 3645 Length of electrical raceway 34 5 8 878 34 5 8 878 Note Electrical field wiring connection point Waste Outlet C Righthand end of case to center of waste outlet 72 1 4 1835 72 1 4 1835 Water Seal Edge of water seal to center of waste outlet 4 102 4 102 Center of waste outlet to outside edge of front b...

Page 3: ...up Control PWR 8 12E CI CO 17 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 11 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb PWR 8 12E 8 ft 2 8 12 ft 4 3 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Ad...

Page 4: ...10 Min Circuit Ampacity With Standard Fans 120V 60Hz 1 74 2 51 With Energy Efficient Fans 120V 60Hz 0 96 1 34 With Export Fans 230V 50 Hz 1 14 1 61 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting Optional Lighting Optional Shelf Lighting None None None Fan Wiring Offtime Defrost 120V POWER 120V NEUTRAL 1 2 3 Fans 120V NEUTRAL BROWN BAND 120V ...

Reviews: