background image

PWR 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

4 of 4

Impact  

PWR

Produce

Electrical Data

Number of Fans

8 ft

12 ft

Refrigeration — 9W

2

3

Refrigeration — 9W (Export)

2

3

Amperes

Watts

Merchandiser

8 ft

12 ft

8 ft

12 ft

Fans (Refrigeration)

Standard (120V 60Hz)

1.54

2.31

124

186

Energy Efficient (120V 60Hz)

0.76

1.14

50

75

Export (230V 50 Hz)

0.94

1.41

140

210

Min. Circuit Ampacity

With Standard Fans (120V 60Hz)

1.74

2.51

With Energy Efficient Fans (120V 60Hz)

0.96

1.34

With Export Fans (230V 50 Hz)

1.14

1.61

Maximum Over Current Protection 120V

20

20

Maximum Over Current Protection 230V

15

15

Standard Lighting

Optional Lighting

Optional Shelf Lighting

None

None

None

Fan  Wiring
Offtime Defrost

=  120V P

OWER

=  120V N

EUTRAL

1, 2 & 3 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

8 ft

12 ft

WARNING

All components must have a mechanical ground, and the merchandiser must be grounded.

CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS     

Summary of Contents for PWR

Page 1: ...cription Wiring Item FAN ASSEMBLIES AND THERMOSTATS A 0378349 Fan Motor Evaporator 1 0142780 Fan Blade Embossing toward motor We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to corresponding changes improvements additions or replacements for equipment previously sold or shipped ...

Page 2: ...Electrical Service B Righthand end of case to center of farthest knockout 95 3 8 2423 143 1 2 3645 Length of electrical raceway 34 5 8 878 34 5 8 878 Note Electrical field wiring connection point Waste Outlet C Righthand end of case to center of waste outlet 72 1 4 1835 72 1 4 1835 Water Seal Edge of water seal to center of waste outlet 4 102 4 102 Center of waste outlet to outside edge of front b...

Page 3: ...up Control PWR 8 12E CI CO 17 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 11 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb PWR 8 12E 8 ft 2 8 12 ft 4 3 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Ad...

Page 4: ...10 Min Circuit Ampacity With Standard Fans 120V 60Hz 1 74 2 51 With Energy Efficient Fans 120V 60Hz 0 96 1 34 With Export Fans 230V 50 Hz 1 14 1 61 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting Optional Lighting Optional Shelf Lighting None None None Fan Wiring Offtime Defrost 120V POWER 120V NEUTRAL 1 2 3 Fans 120V NEUTRAL BROWN BAND 120V ...