background image

3 of 4

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0417991A

Impact  

PWWEE

Produce

Produce Wide Island End, 1 Display Level

44

(1118)

30 

3

/

8

(772)

15

(381)

30 

1

/

2

(775)

(152)

12 

3

/

8

(314)

26 

3

/

8

(670)

7

/

8

(149)

19 

1

/

2

(495)

17

(432)

43 

3

/

8

(1101)

16 

5

/

8

(422)

FAN 

COIL 

PWWEE

Optional

Rack

Positions

25 

1

/

2

(648)

17 

3

/

8

(441)

NSF Certification

These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF

®

) Standard #7 requirements.

Dimensions are shown as inches & (mm).

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H.

PWWEE

Discharge Air (°F)

32

Evaporator(°F)

24

Unit Sizing (°F)

22

Btu/hr/case*

PWWEE

Parallel

2725

Conventional

3005

*

For all refrigeration equipment other than

Hussmann, use conventional Btu values.

DEFROST DATA

PWWEE

Frequency (hr)

6

Defrost Water (lb/ft/day)8

(± 15% 

based on case configuration and

product loading).

O

FFTIME

PWWEE

Temp Term (°F)

N/A

Failsafe (minutes)

45

CONVENTIONAL  CONTROLS

Low Pressure Backup Control

CI/CO**

17°/ 7° F

Indoor Unit Only, Pressure Defrost

Termination**

48° F

**Use a Temperature Pressure Chart to

determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lb)***

1.1

***

This is an average for all refrigerant types.

Actual refrigerant charge may vary by

approximately half a pound.

Length Added to Lineup by

Each End/Partition (in.)

1

/

2

Summary of Contents for PWWEE

Page 1: ...scription Wiring Item FAN ASSEMBLIES AND THERMOSTATS A 0378349 Fan Motor Evaporator 1 0142780 Fan Blade Embossing toward motor We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to corresponding changes improvements additions or replacements for equipment previously sold or shipped ...

Page 2: ...ont of base rail and splashguard 4 7 8 124 Waste Outlet Front outside edge of case to center of waste outlet 19 1 2 495 Right outside edge of case to center of waste outlet 31 3 8 797 PWWEE Data Sheet HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A 2 of 4 PWWEE Base Rail Waste Outlet Water Seal Front Access Area 26 3 8 670 43 3 8 1101 17 432 69 1 2 1765 86 1 2 2197 31 3 8 797 17 432 5 7 8 149 1...

Page 3: ...Discharge Air F 32 Evaporator F 24 Unit Sizing F 22 Btu hr case PWWEE Parallel 2725 Conventional 3005 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA PWWEE Frequency hr 6 Defrost Water lb ft day 8 15 based on case configuration and product loading OFFTIME PWWEE Temp Term F N A Failsafe minutes 45 CONVENTIONAL CONTROLS Low Pressure Backup Control CI CO 1...

Page 4: ...8 With Export Fans 230V 50 Hz 0 67 Maximum Over Current Protection 120V 20 Maximum Over Current Protection 230V 15 Standard Lighting Optional Lighting Optional Shelf Lighting None None None PWWEE Data Sheet HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A 4 of 4 Impact PWWEE Produce 120V POWER 120V NEUTRAL Fan Wiring Offtime Defrost WARNING All components must have a mechanical ground and the me...

Reviews: