Rev. 0408
3
HUSSMANN CHINO PRODUCT CONTROL
The serial number and shipping date of all equipment has
been recorded in HUSSMANN’s files for warranty and
replacement part purposes. All correspondence pertaining
to warranty or parts ordering must include the serial number
of each piece of equipment involved, in order to provide
the customer with the correct parts.
Cut & Plan views
Ref. Dome
(Optional)
Light
RGSSFP (S.C)
shown with Optional Refrigerated Rear Storage
Prep/Self-Service
*3
6"
48"
End
Panel
*12
"
12"
30"
Adj. Wire
Racks
Coil
8
1
/
4
"
13"
8"
12"
19
1
/
2
"
*5
"
Elec.
Access
9
7
/
8
"
Condensing
Unit
S.C.
Plan View
48
"
1"
1"
8"
8’-2" (4’-2”, 6’-2”)
CASE FRONT
8"
16
"
8"
REFRIG.
MECHANICAL
STUB UP AREA
none
16
"
CONDENSING
UNIT
DRAIN & ELEC.
MECHANICAL
STUB UP AREA
18" X 18"
LOCATION
The refrigerated merchandisers have been designed
for use only in air conditioned stores where temperature
and humidity are maintained at or below 75°F and 55%
relative humidity. DO NOT allow air conditioning, electric
fans, ovens, open doors or windows (etc.), to create air
currents around the merchandiser, as this will impair its
correct operation.
Product temperature should always be maintained at a
constant and proper temperature. This means that from the
time the product is received, through storage, preparation
and display, the temperature of the product must be
controlled to maximize life of the product.
UNCRATING THE STAND
Place the fixture as close to its permanent position as
possible . Remove the top of the crate. Detach the walls
from each other and remove from the skid. Unbolt the case
from the skid. The fixture can now be lifted off the crate
skid.
Lift only at base of stand!
EXTERIOR LOADING
These models have
not
been structurally designed to
support excessive external loading.
Do not walk on their
tops;
This could cause serious personal injury and damage
to the fixture.
AVOID REMOVING CONCRETE
All cases were leveled and joined prior to shipment to ensure closest possible
fit when cases are joined in the field. To avoid removing concrete flooring,
begin lineup at highest point of store floor.
LEvELING
IMPORTANT! It is imperative that cases be leveled from
front to back and side to side prior to joining. A level
case is necessary to insure proper operation.
JOINT TRIM
After the case has been leveled and joined, and
refrigeration, electrical, and waste piping work completed,
install the splash guards. Fasten along the top edge, or
center, with #10 X 3/8" sheet metal screws.
Do Not Seal Joint Trim To Floor!
Plumbing
WASTE OUTLET AND P-TRAP
The waste outlet is located off the center of the case on
one side allowing drip piping to be run lengthwise under
the fixture.
A 1-1/" P-trap and thread adapter are supplied with each
fixture. The P-trap must be installed to prevent air leakage
and insect entrance into the fixture.
NOTE: PvC-D Wv solvent cement is recommended.
Follow the manufacturer's instructions.
INSTALLING CONDENSATE DRAIN
Poorly or improperly installed condensate drains can
seriously interfere with the operation of this refrigerator, and
result in costly maintenance and product losses. Please
follow the recommendations listed below when installing
condensate drains to insure a proper installation:
1 . Never use pipe for condensate drains smaller than
the nominal diameter of the pipe or P-trap supplied
with the case.
. When connecting condensate drains, the P-trap
must be used as par t of the condensate drain to
prevent air leakage or insect entrance. Store plumb-