4-4
S
TART UP
/ O
PERATION
PROCEDURE FOR INSTALLING LIGHTED
SHELVES WITH SINGLE-PRONG
CONNECTOR
Shelf lighting uses parallel
wiring. Please follow these
instructions to ensure good
contact between male and
female connectors.
1.
SHUT OFF POWER TO CASE. REMOVE
ALL SHELVES.
2.
Engage each power socket cap and ensure
that each cap is fully seated before cleaning.
Ensure the proper seating of the cap at all
times when the plug is not engaged
.
3. Clean the merchandiser as described in the
Care and Cleaning
paragraphs of
Section 5 –
Maintenance
.
Keep liquid out of sockets.
4. Verify that power is at the case and turned on.
Verify that the case light switch is turned
“OFF.”
Switch is located in the canopy, on
the left, behind first row of lamps.
5. The illustration below shows a typical case.
Note that other models will have fewer rows
of shelves.
Starting from the left-hand bottom section,
choose the location for the first shelf, X-1.
Secure the shelf in the slotted upright. Make
certain that the shelf is level and that ends are
in the same slot on the left and right upright.
It is important that shelf brackets be proper-
ly seated in the slotted upright.
P/N 0446551_A
WWW
.
HUSSMANN
.
COM
Socket with Cap Installed
6 Sockets in
8 ft (2438 mm) Case
9 Sockets in
12 ft (3658 mm) Case
Always work Left to Right, and Bottom to Top
X-1
X-4
X-7
X-2
X-5
X-8
X-3
X-6
X-9
Canopy Light Switch Location
R
I
G
H
T
W
R
O
N
G
Example