Island & Multi-deck Island
P/N 0446551_A
1-3
2. Set first half of case. Case must be shimmed
under legs where case is strongest.
3. Set second half of case as close as possible to
the first, and level second half to the first
using the instructions in step one.
4. Apply liberal bead of case joint sealant (gray
silicone) to side of first half. Apply silicone
along outline, as illustrated.
Do not use
Permagum!
Permagum does not allow cases
to draw up tight, and therefore leaves gaps at
the joint. The case must be shimmed under
base where support is best to prevent damage
to case.
5. Slide second case up to first case snugly.
6. Verify the plexiglass is aligned. See plexiglass
joining instructions (
Finishing Touches
sec-
tion) for more information.
7. To compress silicone at joint, use two
Jurgenson wood clamps to pull the inside of
the bulkheads together. Make sure case is
level from front to back and side to side on
inside bulkheads at joint. Do not place levels
on display pans or on shelves.
Do not use
bolts to draw cases tight! Damage may
occur.
8. Make sure cases are tight and bolted together
in all places (see diagram). Remove clamps.
9. Split (or end) cases such as RIE and SIE have
an interlock system built into the CAD tower.
Joining involves a number of bolts, dependent
on the height of the tower.
FINISHING TOUCHES
After the merchandiser has been leveled and
re-joined, and all drip piping, electrical and
refrigeration work has been completed, finish the
plexiglass joining and install the splashguards.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Avoid removing concrete!
Begin lineup at highest point of store floor.
All cases were leveled and joined prior to
shipment to ensure closest possible fit
when cases are re-joined in the field.
CAUTION
!
Feed CAD Tower
Bolts In
Through Front
Bolt
Locations
Silicone
Sealant
Bead
Bolt and Sealant Locations
Proper case joint sealing is extremely
important to prevent water leaks.
INSTALLER