3 of 6
P/N 0492430_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
27
(686)
49
(1245)
23
7/8
(607)
5
1/2
(140)
60
(1524)
5
1/2
(140)
27
1/8
(689)
55
3/4
(1416)
3
1/4
(83)
9
7/8
(251)
6
(152)
18
1/8
(460)
3
(76
)
5
7/8
(149)
21
1/2
(546)
12
(305)
8
(203)
Dimensions shown as in. and (mm).
REFRIGERATION DATA
Note:
This data is based on store tempera-
ture and humidity that does not exceed
75
°
F and 55% R.H.
RI2N
Discharge Air (°F)
27
Evaporator (°F)
20
Unit Sizing (°F)
18
Btu/hr/ft
L
IT
& U
NLIT
S
HELVES
RI2N
Parallel
1444
Conventional
1575
DEFROST DATA
RI2N
Frequency (hr)
4
Defrost Water (lb/ft/day)
10
(± 15%
based on case configuration and
product loading).
O
FF
T
IME
RI2N
Time Terminated (minutes)
20
E
LECTRIC OR
G
AS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO
*
RI2N
14°F / 4°F
Indoor Unit Only, Pressure Defrost
Termination*
48°F
*Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
1
1
/
2
Merchandiser Liquid Line (in.)
3
/
8
Merchandiser Suction Line (in.)
5
/
8
Estimated Charge (lb)**
8 ft
1.7
10 ft
2.1
12 ft
2.5
14 ft
3.1
16 ft
3.7
**This is an average for all refrigerant types.
Actual refrigerant charge may vary
by approximately half a pound.
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation
Foundation (NSF
®
) Standard #7 requirements.
Multi-deck Island, 3 Display Levels, Narrow Footprint
RI2N
RI2N
Multi-deck Island
Load Limit
Load Limit
Optional High Plex
with 6 in. (152 mm)
Product Depth
Optional Shelves
RI2N
Load Limit Profile
Air flow between the shelves, from the CAD to the return, must be maintained at all times
for optimum operating efficiency and to prolong product shelf life. At no time should
merchandisers be stocked beyond the load limits indicated.
Cases may not function properly if they are loaded above load limits.