P/N 0492426_B

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

18

 1/8

 

(460)

51

 3/4

 

(1315)

9

 7/8

 

(251)

6

 (152)

14

 1/8

 

(359)

11

 1/2

 

(292)

49

 

(1245)

72

 

(1829)

11

 1/2

 

(292)

10

 7/8

 

(276)

1/4

 

(83)

5

 

7/8

 

(149)

(76)

27 

(686)

8

 

(203)

12 

(305)

16 

(406)

Dimensions shown as in. and (mm).

REFRIGERATION DATA

Note: 

This data is based on store tempera-

ture and humidity that does not exceed
75

°

F and 55% R.H. 

RI3

Discharge Air (°F)

27

Evaporator (°F)

20

Unit Sizing (°F)

18

Btu/hr/ft

L

IT

& U

NLIT

S

HELVES

RI3

Parallel

1820

Conventional

1985

DEFROST DATA

RI3

Frequency (hr)

4

Defrost Water (lb/ft/day)

12

(± 15% 

based on case configuration and 

product loading).

O

FF

T

IME

RI3

Time Terminated (minutes)

20

E

LECTRIC OR

G

AS

Not Recommended 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

*

RI3

14°F / 4°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to 
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

5

/

8

Estimated Charge (lb)**

8 ft 

1.7

10 ft 

2.1

12 ft 

2.5

14 ft

3.1

16 ft

3.7

**This is an average for all refrigerant types.
Actual refrigerant charge may vary 
by approximately half a pound.

RI3

Multi-deck Island

NSF Certification

These merchandisers are manufactured to meet ANSI /National Sanitation
Foundation (NSF

®

) Standard #7 requirements. 

Multi-deck Island, 4 Display Levels

RI3

Load Limit

Load Limit

RI3

Optional High Plex 
with 6 in. (152 mm) 
Product Depth

Optional Shelves

Load Limit Profile

Air flow between the shelves, from the CAD to the return, must be maintained at all times
for optimum operating efficiency and to prolong product shelf life. At no time should 
merchandisers be stocked beyond the load limits indicated.

Cases may not function properly if they are loaded above load limits.

Summary of Contents for RI3

Page 1: ...47 CT 4481631 Item Part Description Wiring Item HEATERS C Anti Sweat Heater 3 0487118 HE 4850668 LAMPS AND BALLASTS D Ballast Electronic 4 0355398 BA 4480118 0355716 BA 0355716 0447740 BA 4481278 0459491 BA 4481566 E Fluorescent Lamp 5 Replace with like fixtures 2006 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 1919 MEXICO 1 800 522 1900 WWW HUSSMANN COM We reserve the r...

Page 2: ...8 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knockout 69 1753 93 ...

Page 3: ...e Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 5 8 Estimated Charge lb 8 ft 1 7 10 ft 2 1 12 ft 2 5 14 ft 3 1 16 ft 3 7 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound RI3 Multi deck Islan...

Page 4: ...0 57 0 68 84 84 108 132 156 Minimum Circuit Ampacity MCA 120V 60Hz Standard 5 27 6 57 8 20 11 13 12 77 120V 50Hz Standard 5 31 6 81 8 48 11 66 13 33 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 2 61 3 21 3 98 5 36 6 13 230V 60Hz Energy Efficient NA NA NA NA NA Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 1...

Page 5: ...UTRAL R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 8 ft 10 ft 12 ft 14 ft 16 ft 6 8 10 14 16 Fans Fan Wiring Offtime Defrost HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM ...

Page 6: ... G G G G 5 Light Circuits 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers R Red G Green BL Blue B Black W White W B G R R B L B L R B L B L G G G 4 5 5 5 Optional Ledge Light Circuit Typical Shelf Ballast Wiring Maximum lamps per ballast is four 4 Different shelf config...