P/N 0492434_A

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

L

EVI

T

O N

13451-

20 13451-

20

T8

LA

M

P

T8

LA

M

P

L

EVI

T

O N

13451-

20

T8

LA

M

P

13451-

20

L

EVI

T

O N

T8

LA

M

P

L

EVI

T

O N

40

 1/8

 

(1019)

53

 7/8

 

(1674)

9

 7/8

 

(251)

14

 1/8

 

(359)

11

 1/2

 

(292)

11

 1/2

 

(292)

6

 

(152)

49

 

(1245)

72

 

(1829)

10

 7/8

 

(276)

3

 

1/4

 

(83)

5

 

7/8

 

(149)

3

 

 (76)

27

 

 (686)

15 

 

(381)

13 

 

(330)

10 

 

(254)

Dimensions shown as in. and (mm).

REFRIGERATION DATA

Note: 

This data is based on store tempera-

ture and humidity that does not exceed
75

°

F and 55% R.H. 

RI4E

Discharge Air (°F)

27

Evaporator (°F)

20

Unit Sizing (°F)

18

Btu/hr/ft

L

IT

& U

NLIT

S

HELVES

RI4E

Parallel

2292

Conventional

2500

DEFROST DATA

RI4E

Frequency (hr)

4

Defrost Water (lb/ft/day)

12

(± 15% 

based on case configuration and 

product loading).

O

FF

T

IME

RI4E

Time Terminated (minutes)

20

E

LECTRIC OR

G

AS

Not Recommended 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

*

RI4E

14°F / 4°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to 
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

5

/

8

Estimated Charge (lb)**

8 ft 

1.8

10 ft 

2.2

12 ft 

2.6

14 ft

3.2

16 ft

3.8

**This is an average for all refrigerant types.
Actual refrigerant charge may vary 
by approximately half a pound.

RI4E

Multi-deck Island

NSF Certification

These merchandisers are manufactured to meet ANSI /National Sanitation
Foundation (NSF

®

) Standard #7 requirements. 

Multi-deck Island End, 4 Display Levels

RI4E

Load Limit

Load Limit

LEVITON

13451-20

T8

LAMP

13451-20

T8

LAMP

LEVITON

T8

LAMP

13451-20

LEVITON

13451-20

LEVITON

T8

LAMP

RI4E

Optional High Plex 
with 6 in. (152 mm) 
Product Depth

Load Limit Profile

Air flow between the shelves, from the CAD to the return, must be maintained at all times
for optimum operating efficiency and to prolong product shelf life. At no time should 
merchandisers be stocked beyond the load limits indicated.

Cases may not function properly if they are loaded above load limits.

Summary of Contents for RI4-E

Page 1: ... Item Part Description Wiring Item FAN ASSEMBLIES AND THERMOSTATS 8 Ft 10 Ft 12 Ft 14 Ft 16 Ft A 12W Standard Fan Assembly 1 0047000 Fan Motor Evaporator MO 4410103 0142780 Fan Blade FB 0142780 embossing toward motor 12W Energy Efficient Fan Assembly 1 0477655 Fan Motor Evaporator MO 4410546 0142780 Fan Blade FB 0142780 embossing toward motor B Optional Adjustable Refrigeration Thermostat 2 044834...

Page 2: ... 8 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knockout 69 1753 93...

Page 3: ... Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 5 8 Estimated Charge lb 8 ft 1 8 10 ft 2 2 12 ft 2 6 14 ft 3 2 16 ft 3 8 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound RI...

Page 4: ...rd 5 40 6 70 8 00 9 30 10 60 120V 50Hz Standard 6 20 7 70 9 20 10 70 12 20 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 2 60 3 20 3 80 4 40 5 00 230V 60Hz Energy Efficient NA NA NA NA NA Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 15 Standard Lighting 2 Rows of Canopy 1 75 2 22 2 68 3 15 3 62 210...

Page 5: ...TRAL R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 8 ft 10 ft 12 ft 14 ft 16 ft 8 10 12 14 16 Fans Fan Wiring Offtime Defrost HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM ...

Page 6: ... B L B G G G G 5 Light Circuits 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers R Red G Green BL Blue B Black W White W B G R R B L B L R B L B L G G G 3 5 5 5 Optional Ledge Light Circuit W B Typical Shelf Ballast Wiring Maximum lamps per ballast is three 3 Different s...

Reviews: