background image

6 of 6

RI4

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

4

R

R

B L

B L

R

B L

B L

G

G

G

5

5

5

4

R

R

B L

B L

R

B L

B L

G

G

G

5

5

5

B

W

R

R

B L

B L

R

B L

B L

G

G

G

3

5

5

5

3

5

5

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light 

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

 

B

AND

B

W

R

R

B L

B L

R

B L

B

G

G

G

G

5

Light Circuits

=  120V P

OWER

=  120V N

EUTRAL

=  Field G

ROUND

=  Case G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded. 

Circled Numbers = Parts List Item Numbers 

R = Red     G = Green  BL = Blue   B = Black   W = White

 

W

B

G

R

R

B L

B L

R

B L

B L

G

G

G

3

5

5

5

Optional Ledge Light  Circuit 

W

B

Typical Shelf Ballast Wiring

 

Maximum lamps per ballast is three (3). 
Different shelf configurations and different 
case lengths will have more shelf ballasts.

Lighted Shelf Wiring

Summary of Contents for RI4

Page 1: ...Part Description Wiring Item LAMPS AND BALLASTS C Ballast Electronic 3 0459491 Canopy BA 4481566 D Ballast Electronic 4 0447739 T5 Shelf Lamp BA 4480900 0466234 T8 Shelf Lamp 2 BA 4480823 0466235 T8 Shelf Lamp 3 BA 4480901 E Fluorescent Lamp 5 Replace with like fixtures 2006 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 1919 MEXICO 1 800 522 1900 WWW HUSSMANN COM We reser...

Page 2: ...8 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knockout 69 1753 93 ...

Page 3: ...r Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 5 8 Estimated Charge lb 8 ft 1 8 10 ft 2 2 12 ft 2 6 14 ft 3 2 16 ft 3 8 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound R...

Page 4: ...d 4 10 5 40 6 70 8 00 9 30 120V 50Hz Standard 4 70 6 20 7 70 9 20 10 70 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 2 00 2 60 3 20 3 80 4 40 230V 60Hz Energy Efficient NA NA NA NA NA Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 15 Standard Lighting 2 Rows of Canopy 1 75 2 10 2 57 3 03 4 20 320 38...

Page 5: ...ND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost BROWN BAND BROWN BAND 120V POWER Fans 1 120V NEUTRAL BROWN BAND BROWN BAND 8 ft 10 ft 12 ft 14 ft 16 ft 6 8 10 12 14 Fans HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM ...

Page 6: ... B L B G G G G 5 Light Circuits 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers R Red G Green BL Blue B Black W White W B G R R B L B L R B L B L G G G 3 5 5 5 Optional Ledge Light Circuit W B Typical Shelf Ballast Wiring Maximum lamps per ballast is three 3 Different s...

Reviews: