IGIC-RMID-0109
4
Installation
LOCATION
The refrigerated merchandisers have been designed for
use only in air conditioned stores where temperature and
humidity are maintained at or below 75
°
F and 55% rela-
tive humidity. DO NOT allow air conditioning, electric fans,
open doors or windows (etc.) to create air currents around
the merchandiser, as this will impair its correct operation.
Product temperature should always be maintained at a
constant and proper temperature. This means that from
the time the product is received, through storage, prepa-
ration and display, the temperature of the product must
be controlled to maximize life of the product.
UNCRATING THE STAND
Place the fixture as close to its permanent position as
possible. Remove the top of the crate. Detach the walls
from each other and remove from the skid. Unbolt the
case from the skid. The fixture can now be lifted off the
crate skid.
Lift only at base of stand!
EXTERIOR LOADING
These models have
not
been structurally designed to sup-
port excessive external loading.
Do not walk on their
tops
; This could cause serious personal injury and dam-
age to the fixture.
SETTING AND JOINING
The sectional construction of these models enable them
to be joined in line to give the effect of one continuous
display. A joint trim kit is supplied with each joint.
LEVELING
IMPORTANT! It is imperative that cases be
leveled from front to back and side to side prior
to joining. A level case is necessary to insure
proper operation, water drainage , and
plexiglass alignment. Leveling the case cor-
rectly will solve most hinge operation prob-
lems.
NOTE: A. To avoid removing concrete flooring when installing
long lineups, begin lineup leveling from the highest point
of the store floor.
All cases were leveled and joined prior to shipment to
insure the closest possible fit when cases are joined in
the field. When joining, use a carpenters level and shim
legs accordingly. Case must be raised correctly, under
legs where support is best, to prevent damage to case.
1. Check floor where cases are to be set to determine
the highest point of the floor; cases will be set off
this point.
2. Set first case, and adjust legs over the highest part of
the floor so that case is level. Prevent damage – case
must be raised under leg or by use of 2x6 or 2x4 leg
brace. Remove side and back leg braces after case is
set.
3. Set second case as close as possible to the first case,
and level case to the first using the instructions in
step one.
5. Apply liberal bead of case joint sealant (gray silicone)
to side of firs case. Apply along dotted area shown in
diagram (Fig.2, #1) of first case. Apply heavy amount
to cover entire shaded area
.
DO NOT USE PERMAGUM!
It is the contractor's
responsibility to install
case(s) according to local
construction and health
codes.
6. Slide second case up to first case snugly. Then level
second case to the first case so glass front, bumper
and top are flush.
8. Attach sections together as illustrated in diagram 2-
1.
Diagram 2-1
1
2
3
CAD tower bolts
(if applicable)
Silicone sealant
Lower bolt
locations
Plumbing
WASTE OUTLET AND P-TRAP
The waste outlet is located off the center of the case on
one side allowing drip piping to be run lengthwise under
the fixture.
A 1-1/2" P-trap and threaded adapter are supplied with
each fixture. The P-trap must be installed to prevent air
leakage and insect entrance into the fixture.
NOTE: PVC-DWV solvent cement is recommended.
Follow the manufacturer’s instructions.
INSTALLING CONDENSATE DRAIN
Poorly or improperly installed condensate drains can se-
riously interfere with the operation of this refrigerator,
and result in costly maintenance and product losses. Please
follow the recommendations listed below when installing