IGSSB-SCSS / SCSS-SL-0108
14
Maintenance
ELECTRICAL PRECAUTIONS
BEFORE SERVICING – Always disconnect
electrical power at the main disconnect when
servicing or replacing any electrical component
This includes (but not limited to) Fans, Heaters,
Thermostats, and Lights.
REPLACING FLUORESCENT LAMPS
Fluorescent lamps are furnished with a shatterproof pro-
tective coating. The same type of lamp with protective
coating must be used if replaced.
This lamp has been treated to resist breakage and must be
replaced with a similarly treated lamp in order to maintain
compliance with NSF Standards. NSF CODE 4.28.1
Contact HUSSMANN Chino for replacement
1-800-395-9229 x 2131
T-5 BULBS
Please note: T-5 lights must be turned off and on
after
bulb
replacement.
EVAPORATOR FANS
The evaporator fans are located at the center front of
these merchandisers directly beneath the display pans.
Should fans or blades need servicing, always replace fan blades
with the raised embossed side of the blade TOWARD THE
MOTOR.
COPPER COILS
The copper coils used in Hussmann merchandisers may
be repaired in the field. Materials are available from local
refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.
TIPS & TROUBLESHOOTING
Before calling for service, check the following:
1. Check electrical power supply to the equipment for
connection.
2. Check fixture loading. Overstocking case will affect
its proper operation.
3. If frost is collecting on fixture and/or product, check
that Humidity Control is working properly, and that
no outside doors or windows are open—allowing
moisture to enter store.
FOR PROMPT SERVICE
When contacting the factory,
be sure to have the Case Model and Serial
Number handy. This information is on a plate
located on the case itself.
Electrical and Refrigeration Specifications
Model
Refrigeration
Average
Disch. Air
T~Stat
Coil Type
Fan Blade
Defrosts
Electrical Load (Amps) @ ~115 VAC
Condensing Unit Data
&
Btu / Hr.
Temperatures (
°
F)
Speed
Settings
Size (in) &
Evap.
Motors
per day
Evap.Fans Case
Case
Defrost
Glass
Set (PSI)
Size
Voltage
Ampacity
Length
(Ft.)
(Total)
Evap.
Prod.
Disch.
(CFM)
(
°
F)
pitch (
°
)
Fans
Qty
Length Qty
Fans Warmer
Lights
Heater
Heater
Out
In
(HP)
(VAC)
SCSS-M Medium Temperature
4'
650
2,600
20
°
40
°
30
°
200
Optional Forced Air
4" Axial
2
30
2
0.28 0.35
0.54
30
50
1/2
115
13.6
5'
650
3,250
20
°
40
°
30
°
200
Optional Forced Air
4" Axial
2
30
2
0.28 0.43
0.54
30
50
3/4
115
18.5
6'
650
3,900
20
°
40
°
30
°
200
Optional Forced Air
4" Axial
3
30
2
0.42 0.52
0.54
30
50
3/4
115
18.5
8'
650
5,200
20
°
40
°
30
°
200
Optional Forced Air
4" Axial
4
30
2
0.56 0.70
0.54
30
50
1
208~230 11.8
SCSS-M Low Temperature
4'
800
3,200
-25
°
-10
°
-20
°
200
Optional Forced Air
4" Axial
2
20
1
0.28 0.35
0.54
5.77
0.42
30
50
1-1/2
208
14.7
5'
800
4,000
-25
°
-10
°
-20
°
200
Optional Forced Air
4" Axial
2
20
1
0.28 0.43
0.54
9.62
0.52
30
50
1-1/2
208
14.7
6'
800
4,800
-25
°
-10
°
-20
°
200
Optional Forced Air
4" Axial
3
20
1
0.42 0.52
0.54
9.62
0.63
30
50
1-1/2
208
14.7
8'
800
6,400
-25
°
-10
°
-20
°
200
Optional Forced Air
4" Axial
4
20
1
0.56 0.70
0.54
10.82
0.63
30
50
2
208
12.8
SCSS-SLM
Slim Line - Medium Temperature
4'
540
2,160
20
°
40
°
30
°
200
Optional Forced Air
4" Axial
2
30
2
0.28 0.35
0.54
30
50
1/2
115
13.6
5'
540
2,700
20
°
40
°
30
°
200
Optional Forced Air
4" Axial
2
30
2
0.28 0.43
0.54
30
50
3/4
115
18.5
6'
540
3,240
20
°
40
°
30
°
200
Optional Forced Air
4" Axial
3
30
2
0.42 0.52
0.54
30
50
3/4
115
18.5
8'
540
4,320
20
°
40
°
30
°
200
Optional Forced Air
4" Axial
4
30
2
0.56 0.70
0.54
30
50
1
208 ~ 23011.8
SCSS-SLLSlim Line - Low Temperature
4'
625
2,500
-25
°
-10
°
-20
°
200
Optional Forced Air
4" Axial
2
20
1
0.28 0.35
0.54
5.77
0.42
30
50
1-1/2
208
14.7
5'
625
3,125
-25
°
-10
°
-20
°
200
Optional Forced Air
4" Axial
2
20
1
0.28 0.43
0.54
9.62
0.52
30
50
1-1/2
208
14.7
6'
625
3,750
-25
°
-10
°
-20
°
200
Optional Forced Air
4" Axial
3
20
1
0.42 0.52
0.54
9.62
0.63
30
50
1-1/2
208
14.7
8'
625
5,000
-25
°
-10
°
-20
°
200
Optional Forced Air
4" Axial
4
20
1
0.56 0.70
0.54
10.82
0.63
30
50
2
208
12.8
Summary of Contents for SCSS