P/N 0515154_E
4-3
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
SHM Merchandisers
CLEANING THERMOMETER
Remove the two screws holding the thermometer
to its mounting bracket. Remove the sensing
element from its clip. Clean the element with
water and mild detergent solution. Ensure the
sensing element is wiped clean of any residue to
ensure proper temperature readings.
CLEANING COILS
Condenser coils should be cleaned at least
once per month. Additional cleaning may be
needed depending on the operational environ-
ment. A dirty condenser blocks normal airflow
through the coils.
Airflow blockage increases energy consump-
tion and reduces the merchandiser’s ability to
maintain operating temperature.
To clean the coils, use a vacuum cleaner with a
wand attachment and a soft (non-metallic)
brush to remove dirt and debris. Do not bend
coil fins. Always wear gloves and protective eye
wear when cleaning near sharp coil fins and
dust particles.
SHUT FANS OFF DURING
CLEANING PROCESS.
Do NOT use HOT water on Cold glass Surfaces.
This can cause the glass to shatter and could
result in personal injury. Allow glass fronts, to
warm before applying hot water.