P/N 0515154_E
U.S. & Canada 1-800-922-1919 • Mexico 01 800-890-2900 • www.hussmann.com
REPLACING LIGHTS
There is a convenient ON/OFF switch located
on the light bar. This switch only controls the
lights. ALWAYS disconnect electrical power
when replacing lights or lighting parts.
SHM merchandisers are available with optional
LED lights. The bulb is sleeved to protect the
lights from damage. If these bulbs need to be
replaced, slide the prongs clear of the lamp
holder. Ensure that the prongs on the replace-
ment bulb twist and lock into place.
REPLACING BALLAST / POWER SUPPLY
LED fixture replacement follows the same
steps as fluorescent bulbs. However, LED
fixtures have the sleeve built in as a single
assembly. The LED power supply is also
located in the condensing unit electrical box.
Fluorescent lamps contain mercury vapor.
Mercury exposure at high levels can harm
the brain, heart, kidneys, lungs, and
immune system of people of all ages. Do
not break or puncture fluorescent lamps.
Dispose of, or store, all fluorescent lamps
in accordance with Federal (40 CFR 273),
State, and local hazardous waste require-
ments. Refer to:
http://www.epa.gov/mercury/about.htm