17
BAKERY SERVICE VERTICAL GLASS WITH DRAWER
REVISION DATE 03/05/18
HUSSMANN - SHVSV-DWR (CHINO)
REFRIGERATION DATA:
NSF 7
AHRI 1200
NSF 7
AHRI
1200
3',4',5',6',8',10',12'
450
450
20
20
3'
0.3
0.5
1.2
45° IS
2900
2900
20
20
4'
0.5
0.7
2.0
5'
0.7
0.9
3.0
6'
0.9
1.0
1.4
8'
1.1
1.4
1.5
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
10'
1.4
1.7
1.4
***REFRIGERATION NOTES:
12'
1.6
2.0
1.2
1) BTU'S DO NOT INCLUDE LIGHTS
45° IS
0.5
1.1
1.3
2) ADD 10 BTU'S PER FOOT/PER SHELF ROW FOR OPTIONAL LED SHELF LIGHTS
3) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY
4) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
5) RATING CONDITION IS NSF TYPE I, 75°F/55% RH
REFRIGERATION DATA CONTINUED:
1
1.125
BAKERY
26
23
OFF TIME
40
45
NA
2
1.125
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
3'
3
0.12
14
2
0.08
9
0.24
27
0.20
23
0.44
50
0.87
100
1
115
15
4'
3
0.12
14
2
0.08
9
0.32
37
0.27
31
0.59
68
1.04
120
1
115
15
5'
4
0.16
19
2
0.08
9
0.41
47
0.34
39
0.75
86
1.09
125
1
115
15
6'
6
0.25
28
4
0.16
19
0.47
54
0.40
46
0.87
100
1.57
180
1
115
15
8'
6
0.25
28
4
0.16
19
0.65
74
0.54
62
1.18
136
2.09
240
1
115
15
10'
8
0.33
38
4
0.16
19
0.82
94
0.68
78
1.49
172
2.63
303
1
115
15
12'
9
0.37
42
6
0.25
28
0.97
112
0.81
93
1.78
204
3.13
360
2
115
30
45° IS
4
0.16
19
2
0.08
9
0.32
37
0.26
29
0.57
66
0.65
75
N/A
N/A
N/A
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
DRAWERS
AMPS WATTS
AMPS
WATTS
AMPS
WATTS
3'
0.32
37
0.29
34
0.61
70
3'
4'
0.41
47
0.35
41
0.76
88
4'
5'
N/A
N/A
N/A
N/A
N/A
N/A
5'
6'
0.64
73
0.59
67
1.22
141
6'
8'
0.82
94
0.71
81
1.53
176
8'
10'
N/A
N/A
N/A
N/A
N/A
N/A
10'
12'
1.23
141
1.06
122
2.29
264
12'
45° IS
N/A
N/A
N/A
N/A
N/A
N/A
45° IS
3
2
1
1
2
2
2
CASE
LENGTH
NUMBER OF
DRAWERS
1
AMPS
WATTS
#
OUTLETS
VOLTS AMPS
WATTS AMPS
WATTS
OPTIONAL
LED SHELF
LIGHTS
MAX. LED LOAD
(W/ ALL OPTIONS)
AMPS
0.75~1
HEATERS
END PNL
WIDTH
(IN.)
BAKERY
END PANEL WIDTH KEY
1.125
DEFROST
WATER
(LBS/DAY/FT)
# OF END
PNLS
2.25
CONVENIENCE
OUTLETS (OPTIONAL)
BAKERY
CUT IN
(ºF)
USAGE
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
CUT
OUT
(ºF)
CASE LENGTHS/
WEDGES
CASE USAGE
NSF 7
RATING CONDITION EVAPORATOR
DISCHARGE
AIR ** (°F)
TEMPERATURE (ºF)
CAPACITY ***
(BTU/HR/FT) (TOTAL
FOR WEDGES)
EST.
REFG.
CHRG.
(LBS)
PSI
GPM
20°F GLYCOL
6° RISE
TOTAL ADDED
LENGTH (IN.)
250~300
250~300
25~27
VELOCITY
(FT/MIN)
CASE
LENGTHS
24~26
NSF 7
CANOPY
LIGHTS
H.O. LED
OPTIONAL SHELF
H.O LED
MAX. H.O. LED
LOAD
DEFROST
TYPE
TIME
(MIN)
AIRSWEEP FANS,
4.7" AXIAL FAN
CASE LENGTH
CASE LENGTH
DRIP
TIME
TERM.
TEMP
(°F) COIL
ONLY
DEFROST
FREQUENCY
(#/DAY)
CANOPY
LIGHTS LED
# OF
EVAP
FANS
AMPS
WATTS
AMPS WATTS
6
# OF
FANS
AMPS
WATTS
EVAPORATOR FANS,
4.7" AXIAL FAN
36 3/8"
38 3/8"
2"
24"
26"
15"
20 1/4"
51 3/4"
10"
13 1/4"
22"
+3" RAISED BASE
30 1/4"
9 7/8"
CLEAR
29 1/2"
26"
SLIDE-OUT DECK
5 1/8"
1 3/8"
3 1/2"
6"
3 1/8"
20"
38 1/2"
1 1/8"
1 1/8"
36"
REFRIG.
4"
8"
GFCI
RECEPTACLES
(OPTIONAL)
SHVSV-DWR-3-R
L
C
1 3/8"
3 1/2"
REAR OF CASE (SERVER SIDE)
FRONT OF CASE (CUSTOMER SIDE)
DRAIN
ELECT
FRONT
CLOSE-OFF
Ele
ct
Refrig
Drain
8"
4"
L
C
20"
4 1/8"
6"
3 1/8"
38 1/2"
39 7/8"
39 7/8"
SHVSV-DWR-45I-R
EFR #1338
2"
*DRAWER LOAD RATING: 30 LB/FT
Refrigeration Spec Sheets
Summary of Contents for SHVSV Series
Page 9: ...9 Joint Trim Pack list ...
Page 20: ...20 Electrical Wiring Diagram 0 0 0 1 0 0 0 0 2 0 0 3 0 0 1 1 1 1 1 ...
Page 21: ...21 Electrical Wiring Diagram Cont d 0 1 1 1 2 0 1 1 0 1 1 3 0 1 1 4 0 1 1 2 2 2 2 ...
Page 24: ...24 0 1 1 1 2 0 1 1 0 1 1 2 3 0 1 1 4 0 1 1 2 2 2 2 2 2 2 2 Electrical Wiring Diagram Cont d ...