SI1 Island

A

B

Electrical Service

Drains

Refrigeration 

& Coil Stubout

32

 

1

/2

 

(826)

27 

(686)

(178)

49 

(1242)

11

 

1

/2

 

(292)

9

 

1

/2

 

(241)

22 

(559)

72

 

(1829)

31

 

(788)

20

 

1

/2

 

(521)

Engineering

Plan Views

06-2003

Front

Serial Plate
End

8 ft

10 ft

12 ft

14 ft

16 ft

General

(A)

Base Length

77 (1956)

101 

7

/

(2588)

125 

7

/

(3198)

149 

1

/

(3798)

173 (4396)

Overall Case Length

96 (2438)

120 (3048)

144 (3658)

168 (4267)

192 (4876)

Maximum O/S dimension of case back to front 

(includes bumper)

72 (1829)

72 (1829)

72 (1829)

72 (1829)

72 (1829)

Front of splashguard to O/S edge of front base rail

5

/

(41)

5

/

(41)

5

/

(41)

5

/

(41)

5

/

(41)

Front of case to O/S edge of front base rail

13 

1

/

(333)

13 

1

/

(333)

13 

1

/

(333)

13 

1

/

(333)

13 

1

/

(333)

Back of case to O/S edge of front base rail

58 

7

/

(1495)

58 

7

/

(1495)

58 

7

/

(1495)

58 

7

/

(1495)

58 

7

/

(1495)

Width of base rail

7

/

(48)

7

/

(48)

7

/

(48)

7

/

(48)

7

/

(48)

Electrical Service                             

(Electrical Field Wiring connection point)

Center of Electrical service to O/S edge of front base rail

46 

1

/

(1181)

46 

1

/

(1181)

46 

1

/

(1181)

46 

1

/

(1181)

46 

1

/

(1181)

Right end of case to center of knockout

27 (686)

27 (686)

27 (686)

27 (686)

27 (686)

Left end of case to center of knockout

69 (1753)

93 (2362)

117 (2972)

141 (3581)

165 (4191)

Waste Outlets

(B)

LH End of case to the center of waste outlet

48 (1219)

78 (1981)

102 (2591)

84 (2134)

96 (2439)

Center of front waste outlet to outside of front base rail

8 (203)

8 (203)

8 (203)

8 (203)

8 (203)

Center of back waste outlet to outside of front base rail

39 

1

/

(997)

39 

1

/

(997)

39 

1

/

(997)

39 

1

/

(997)

39 

1

/

(997)

Schedule 40 PVC drip pipe

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

Refrigeration Outlet

LH end of case to center of refrigeration outlet

22 (559)

22 (559)

22 (559)

22 (559)

22 (559)

RH end of case to center of refrigeration outlet

74 (1880)

98 (2489)

122 (3098)

146 (3708)

170 (4318)

Summary of Contents for SI1

Page 1: ...Adjustable Refrigeration Thermostat 2 0448347 CT 4481631 Item Part Description Wiring Item HEATERS C Anti Sweat Heater 3 0447688 HE 4850682 LAMPS AND BALLASTS D Ballast Electronic 4 0447683 BA 4440811 E Fluorescent Lamp 5 Replace with like fixtures 2007 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 1919 MEXICO 1 800 522 1900 WWW HUSSMANN COM We reserve the right to change...

Page 2: ... 7 8 1495 58 7 8 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knock...

Page 3: ...beyond the load limits indicated Cases may not function properly if they are loaded above load limits REFRIGERATION DATA Note This data is based on store tempera ture and humidity that does not exceed 75 F and 55 R H SI1 Discharge Air F 27 Evaporator F 15 Unit Sizing F 13 Btu hr ft SI1 Parallel 1260 Conventional 1375 DEFROST DATA SI1 Frequency hr 4 Defrost Water lb ft day 9 15 based on case config...

Page 4: ...tandard 1 00 1 00 1 33 1 67 2 00 120 120 160 200 240 230V 50 60Hz Export 0 52 0 52 0 70 0 87 1 04 120 120 160 200 240 Minimum Circuit Ampacity MCA 120V 60Hz Standard 3 80 5 10 6 73 8 37 10 00 120V 50Hz Standard 3 72 5 22 6 90 8 57 10 24 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 1 92 2 52 3 30 4 07 4 84 230V 60Hz Energy Efficient NA NA NA NA NA Maxim...

Page 5: ...UTRAL R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 8 ft 10 ft 12 ft 14 ft 16 ft 4 6 8 10 12 Fans Fan Wiring Offtime Defrost HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM ...

Page 6: ...RANGE OR TAN BAND B R R B L B L R B L G G G G 5 Light Circuits 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers R Red G Green BL Blue B Black W White W B G R R B L B L R B L B L G G G 4 5 5 5 Optional Ledge Light Circuit ...

Reviews:

Related manuals for SI1