background image

Serial Plate

P/N 0492444_A

®

SI1N

Technical Data Sheet

P/N 0492444_A

NSF

®

Certified

April 2007

©2007 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

8 Ft, 10 Ft, 12 Ft

,

14 Ft & 16 Ft

A.

12W Standard

Fan Assembly

(1)

0047000

Fan Motor, Evaporator 
(MO.4410103)

0407532

Fan Blade (FB.4780619)
embossing toward motor

12W Energy Efficient

Fan Assembly 

(1)

0477655

Fan Motor, Evaporator
(MO.4410546)

0407532

Fan Blade (FB.4780619)

B. Optional Adjustable Refrigeration Thermostat (2)

0448347

(CT.4481631)

Item Part #

Description

Wiring Item #

H

EATERS

C.

Anti-Sweat Heater

(3)

0447688

(HE.4850682)

L

AMPS AND

B

ALLASTS

D. Ballast, Electronic

(4)

0447683

(BA.4440811)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

Summary of Contents for SI1N

Page 1: ...acements for equipment previously sold or shipped Item Part Description Wiring Item FAN ASSEMBLIES AND THERMOSTATS 8 Ft 10 Ft 12 Ft 14 Ft 16 Ft A 12W Standard Fan Assembly 1 0047000 Fan Motor Evaporator MO 4410103 0407532 Fan Blade FB 4780619 embossing toward motor 12W Energy Efficient Fan Assembly 1 0477655 Fan Motor Evaporator MO 4410546 0407532 Fan Blade FB 4780619 B Optional Adjustable Refrige...

Page 2: ... 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knockout 69 1753 93 2...

Page 3: ...e stocked beyond the load limits indicated Cases may not function properly if they are loaded above load limits REFRIGERATION DATA Note This data is based on store tempera ture and humidity that does not exceed 75 F and 55 R H SI1 Discharge Air F 27 Evaporator F 15 Unit Sizing F 13 Btu hr ft SI1 Parallel 1260 Conventional 1375 DEFROST DATA SI1 Frequency hr 4 Defrost Water lb ft day 9 15 based on c...

Page 4: ...Standard 1 00 1 00 1 33 1 67 2 00 120 120 160 200 240 230V 50 60Hz Export 0 52 0 52 0 70 0 87 1 04 120 120 160 200 240 Minimum Circuit Ampacity MCA 120V 60Hz Standard 3 80 5 10 6 73 8 37 10 00 120V 50Hz Standard 3 72 5 22 6 90 8 57 10 24 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 1 92 2 52 3 30 4 07 4 84 230V 60Hz Energy Efficient NA NA NA NA NA Maxi...

Page 5: ...UTRAL R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 8 ft 10 ft 12 ft 14 ft 16 ft 4 6 8 10 12 Fans Fan Wiring Offtime Defrost HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM ...

Page 6: ...ORANGE OR TAN BAND B R R B L B L R B L G G G G 5 Light Circuits 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers R Red G Green BL Blue B Black W White W B G R R B L B L R B L B L G G G 4 5 5 5 Optional Ledge Light Circuit ...