background image

5 of 6

P/N 0492436_A

Light Blue

2

To 
Condensing Unit

}

Refrigeration Thermostat

1

3

Anti-sweat Heaters

B

ROWN

  B

AND

Fans

B

ROWN

  B

AND

120V POWER

1

B

ROWN

  B

AND

B

ROWN

  B

AND

120V NEUTRAL

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  Field G

ROUND

=  Case G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

 
 
 

 

8 ft 

10 ft 
12 ft 
14 ft 
16 ft

4, 6, 8, 10 & 12 Fans

Fan  Wiring 
Offtime Defrost

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

Summary of Contents for SI2N

Page 1: ...uipment previously sold or shipped Item Part Description Wiring Item FAN ASSEMBLIES AND THERMOSTATS 8 Ft 10 Ft 12 Ft 14 Ft 16 Ft A 12W Standard Fan Assembly 1 0047000 Fan Motor Evaporator MO 4410103 0142780 Fan Blade FB 0142780 embossing toward motor 12W Energy Efficient Fan Assembly 1 0477655 Fan Motor Evaporator MO 4410546 0142780 Fan Blade FB 0142780 B Optional Adjustable Refrigeration Thermost...

Page 2: ... 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knockout 69 1753 93 2...

Page 3: ...d the load limits indicated Cases may not function properly if they are loaded above load limits REFRIGERATION DATA Note This data is based on store tempera ture and humidity that does not exceed 75 F and 55 R H SI2N Discharge Air F 27 Evaporator F 20 Unit Sizing F 18 Btu hr ft LIT UNLIT SHELVES SI2N Parallel 1444 Conventional 1575 DEFROST DATA SI2N Frequency hr 4 Defrost Water lb ft day 12 15 bas...

Page 4: ...30V 50Hz Export 0 37 0 37 0 47 0 57 0 68 84 84 108 132 156 Minimum Circuit Ampacity MCA 120V 60Hz Standard 3 97 5 27 6 90 8 53 10 17 120V 50Hz Standard 3 81 5 31 6 98 8 66 10 33 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 2 01 2 61 3 38 4 16 4 93 230V 60Hz Energy Efficient NA NA NA NA NA Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over...

Page 5: ...UTRAL R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 8 ft 10 ft 12 ft 14 ft 16 ft 4 6 8 10 12 Fans Fan Wiring Offtime Defrost HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM ...

Page 6: ...B G G G G 5 Light Circuits 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers R Red G Green BL Blue B Black W White W B G R R B L B L R B L B L G G G 4 5 5 5 Optional Ledge Light Circuit Typical Shelf Ballast Wiring Maximum lamps per ballast is four 4 Different shelf confi...

Reviews: