iGfp-cr3fo-1209
10
electrical
Wiring color code
CASE MUST BE GROUNDED
NOTE: Refer to label affixed to case to determine the actual
configuration as checked in the “TYPE INSTALLED”
boxes.
Electrical Circuit Identification
Standard lighting for all refrigerated models will be full
length fluorescent lamps located within the case at the
top.
The switch controlling the lights, the plug provided for
digital scale, and the thermometer are located at the rear
of the case mullion.
The receptacle that is provided on the exterior back of these
models is intended for computerized scales with a five amp
maximum load, not for large motors or other high wattage
appliances. It should be wired to a dedicated circuit.
electrical service receptacles (When applicable)
The receptacles located on the exterior of the merchandiser
are intended for scales and lighted displays. They are not
intended nor suitable for large motors or other external
appliances.
field Wiring and serial plate amperage
Field Wiring must be sized for component amperes printed
on the serial plate. Actual ampere draw may be less than
specified. Field wiring from the refrigeration control panel to
the merchandisers is required for refrigeration thermostats.
Case amperes are listed on the wiring diagram, but always
check the serial plate.
Ballast location
Ballasts are located within the access panel that runs the
length of the rear of the case.
Fluorescent Lamp Disposal:
The United States Envi-
ronmental protection Agency has information regarding
environmentally-safe fluorescent lamp waste manage-
ment programs.
On the Net: EPA Web site:
http://www.epa.gov/osw/hazard/wastetypes/universal/lam
ps/recycle.htm
fluorescent lamp disposal:
The United States
Environmental Protection Agency has information
regarding environmentally-safe fluorescent lamp
waste management programs.
On the Net: EPA Website:
http://www.epa.gov/osw/hazard/wastetypes/
universal/lamps/recycle.htm