iGFC-Cr3H-HtB-0508
4
location
The refrigerated merchandisers have been designed for
use only in air conditioned stores where temperature and
humidity are maintained at or below 75°F and 55% relative
humidity. DO NOT allow air conditioning, electric fans, open
doors or windows (etc.) to create air currents around the
merchandiser, as this will impair its correct operation.
Product temperature should always be maintained at a
constant and proper temperature. This means that from the
time the product is received, through storage, preparation
and display, the temperature of the product must be
controlled to maximize life of the product.
uncrating the Stand
Place the fixture as close to its permanent position as
possible. Remove the top of the crate. Detach the walls from
each other and remove from the skid. Unbolt the case from
the skid. The fixture can now be lifted off the crate skid.
lift
only at base of stand!
exterior loading
These models have
not
been structurally designed to
support excessive external loading.
Do not walk on their
tops;
This could cause serious personal injury and damage
to the fixture.
GLASS BREAKAGE MAY OCCUR
Retighten glass along clamshell after
leveling and first time case is brought
to full operating temperature!
Glass adjustment
During shipment, the lubricant inside the cylinders may
have settled. This settling may cause excessive or uneven
tension on the glass - to the point of breakage. To avoid any
damage, please follow these three easy steps:
1. Slowly raise and lower each glass section 6 times to
a height of 6 inches.
. Increase the height to 1 inches, and raise and lower
the glass 6 more times.
3. Finally raise the glass to its full extension, and lower.
These steps should release any settled lubricant within the
cylinders and prevent any stress on the front glass.
leveling
iMportant! it iS iMperative tHat CaSeS anD
SupportinG CounterS Be leveleD FroM
Front to BaCK anD SiDe to SiDe prior to
JoininG. a level CaSe iS neCeSSarY to inSure
proper operation, water DrainaGe, anD
pleXiGlaSS aliGnMent.
NOTE: A. To avoid removing concrete flooring, begin lineup
leveling from the highest point of the store floor.
B. When wedges are involved in a lineup, set them first.
installation
All cases were tested at a level state before shipping.
When joining, use a carpenters level and shim enclosing
or supporting cabinet accordingly.
1. Make sure the cabinet you are installing the FC4H
CINNABON on is level.
. Wire unit according to local codes.
installation
electrical
wiring Color Code
CASE MUST BE GROUNDED
NOTE: Refer to label illustrated above that is affixed to case
to determine the actual configuration as checked in the
“tYpe inStalleD” boxes.
Electrical Circuit Identification
Standard lighting for all models will be full length fluorescent
lamps located within the case at the top.
The switch controlling the lights, the plug provided for
digital scale, and the thermometer are located at the rear
of the case mullion.
The receptacle that is provided on the exterior back of these
models is intended for computerized scales with a five amp
maximum load, not for large motors or other high wattage
appliances. It should be wired to a dedicated circuit.
electrical Service receptacles (when applicable)
The receptacles located on the exterior of the merchandiser
are intended for scales and lighted displays. They are not
intended nor suitable for large motors or other external
appliances.