IGIP-DSI-03, DSRPI-03 & DSI03-Y, DSRPI-03Y-0508
4
Cut and Plan views (Cont'd)
Installation
Location
The refrigerated merchandisers have been designed
for use only in air conditioned stores where temperature
and humidity are maintained at or below 75°F and 55%
relative humidity. DO NOT allow air conditioning, electric
fans, ovens, open doors or windows (etc.) to create air
currents around the merchandiser, as this will impair its
correct operation.
Product temperature should always be maintained at a
constant and proper temperature. This means that from the
time the product is received, through storage, preparation
and display, the temperature of the product must be
controlled to maximize life of the product.
Uncrating the Stand
Place the fixture as close to its permanent position as
possible. Remove the top of the crate. Detach the walls
from each other and remove from the skid. Unbolt the case
from the skid. The fixture can now be lifted off the crate
skid.
Lift only at base of stand!
Exterior Loading
These models have
not
been structurally designed to
support excessive external loading.
Do not walk on their
tops;
This could cause serious personal injury and damage
to the fixture.
Setting and Joining
The sectional construction of these models enable them to
be joined in line to give the effect of one continuous display.
A joint trim kit is supplied with each joint.
Leveling
IMPORTANT! IT IS IMPERATIvE THAT CASES BE
LEvELED FROM FRONT TO BACK AND SIDE TO SIDE
PRIOR TO JOINING. A LEvEL CASE IS NECESSARY
TO INSURE PROPER OPERATION, WATER DRAINAGE,
GLASS ALIGNMENT, AND OPERATION OF THE HINGES
SUPPORTING THE GLASS. LEvELING THE CASE
CORRECTLY WILL SOLvE MOST HINGE OPERATION
PROBLEMS.