9
WIRING COLOR CODE
G R E E N
G RO U N D
P U R P L E
A N T I - S W E AT
O R A N G E
L I G H T S
Y E L L OW
R E C E P TA C L E
R E D / B L A C K
T- S TAT / S O L E N O I D 230V
BLACK / WHITE
T- S TAT / S O L E N O I D 115V
B ROW N
FAN MOTORS
CASE MUST BE GROUNDED
NOTE: Refer to label affixed to case to determine the actual
configuration as checked in the “TYPE INSTALLED” boxes.
Electrical Circuit Identification
Standard lighting for all models will be full length fluores-
cent lamps located within the case at the top.
The switch controlling the lights, the plug provided for
digital scale, and the thermometer are located at the rear
of the case mullion.
The receptacle that is provided on the exterior back of
these models is intended for computerized scales with a
five amp maximum load, not for large motors or other
high wattage appliances. It should be wired to a dedicated
circuit.
ELECTRICAL
Case Specifications
Temperature
Dischg.
Defrost
115 V. Electrical Circuits
Model
Btu
Avg
Air
T-stat/
Evap Fan Size
Freq.
Air
Self Contained Information
/Length
Req’d
Total
Evap
Prod
Disc
Veloc Settings
Coil
Number
&
Evap
Case
Number
PSI
PSI
Size
Voltage
Application
per Ft.
BTU
Tmp
Tmp
Tmp
@Fpm
F°
Type Of Motors
Duration
Fans
Lights
Levels
Out
In
HP
VAC Ampacity
VSG - Dry
4'
Dry Bakery
2.24
4
5'
Dry Bakery
2.24
4
6'
Dry Bakery
5.09
4
VSG - Dry
4'
Dry Bakery
1.73
4
5'
Dry Bakery
2.24
4
6'
Dry Bakery
4.48
4
VSG DSS - Refrigerated Display for Cream Cheese and Related Refrigerated Items - Optional Equipment
5'
Deli
662
3,310
20
35
30
140
30°
Forced 4 1/2" (2)
30
.28
.061
1
30
50
1/3
115
12
Air
Axial
(3)
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT WHEN
SERVICING OR REPLACING ANY ELECTRI-
CAL COMPONENT.
This includes (but not limited to) Fans, Heaters,
Thermostats, and Lights.
FIELD WIRING & SERIAL PLATE AMPERAGE
Field Wiring must be sized for component amperes
printed on the serial plate. Actual ampere draw may be
less than specified. Field wiring from the refrigeration
control panel to the merchandisers is required for re-
frigeration thermostats. Most component amperes are
listed in the “Case Specs” section, but always check the
serial plate.
BALLAST LOCATION
Ballasts are located within the access panel that runs the
length of the rear of the case.