background image

REFRIGERATION DATA

Note: 

This data is based on store

temperature and humidity that does 
not exceed 75

°

F and 55% R.H. 

W6RRI

Discharge Air (°F)

28

Evaporator (°F)

19

Unit Sizing (°F)

17

Important Note:

Btu numbers are for

the W6RRI when installed in a cooler
operating at a 36

°

F air temperature. 

The unit cooler coil must be sized for 
an 

additional load of 1275 Btu/hr/ft 

of W6RRI

case installed in the cooler.

Btu/hr/ft

W6RRI

Roll-in Dairy Carts

Parallel

1225

Conventional

1400

DEFROST DATA

W6RRI

Frequency (hr)

6

Defrost Water (lb/ft/day)

6

(± 15% 

based on case configuration

and product loading).

O

FF

T

IME

W6RRI

Time Terminated (minutes)

45

E

LECTRIC OR

G

AS

Not Recommended 

Standard Defrost Thermostat — NA

CONVENTIONAL CONTROLS

Low Pressure Backup Control

W6RRI

CI/CO (Temp °F)

*

12 / 2

Indoor Unit Only, Pressure Defrost

Termination (Temp °F)*

NA

*Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

7

/

8

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Estimated Charge (lb)**

8 ft 

2.7

12 ft 

3.9

**This is an average for all refrigerant
types. Actual refrigerant charge may
vary by approximately half a pound.

P/N 047

7992

_

A

7

  

(178)

6

 

(152)

Light 

Channel

Honeycomb

2x4 Electrical Box

2x4 

Electrical 

Box

Fans

Fans

Coil

W6RRI

84

 

(2134)

41 

1

/

8 (1045)

48

  (1219)

69

 

(1753)

82 

1

/

(2095)

56 

1

/

4  (1429)

Honeycomb

13

 

(330)

10

  

(254)

Curtain

94

 

(2388)

50 

1

/

2 (1283)

W6RRI

Dairy

Dimensions shown as in. & (mm).

Roll-in Rear Load

3 of 5

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

Summary of Contents for W6RRI

Page 1: ... Item FAN ASSEMBLIES A 25W Energy Efficient Fan Assembly Discharge 0477658 Fan Motor Discharge 1 MO 4410549 0463643 Fan Blade FB 4780648 B 25W Energy Efficient Fan Assembly Return 0477658 Fan Motor Return 2 MO 4410549 0463643 Fan Blade FB 4780648 Item Part Description Wiring Item LAMPS AND BALLASTS C Ballast Electronic 4 0464251 2 lamps BA 4481298 0464252 3 lamps BA 4440509 0464253 4 lamps BA 4481...

Page 2: ...e Electrical Field Wiring Connection Point Back of case to center of 4x4x2 Upper Electrical box 2 3 4 71 2 3 4 71 Back of case to center of 2x4x2 Lower Electrical box 47 7 8 1215 47 7 8 1215 RH End of case to center of 4x4x2 Upper Electrical box 2 50 2 50 RH End of case to center of 2x4x2 Lower Electrical box 5 1 8 132 5 1 8 132 Waste Outlet B RH End of case to the center of LH waste outlet canopy...

Page 3: ...mmended Standard Defrost Thermostat NA CONVENTIONALCONTROLS Low Pressure Backup Control W6RRI CI CO Temp F 12 2 Indoor Unit Only Pressure Defrost Termination Temp F NA Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 7 8 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 8 ft 2 7 12 ft 3 9 This is an average fo...

Page 4: ... 230V 60Hz Energy Efficient 3 80 5 60 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting 2 Row Canopy 1 02 1 54 118 170 Optional Lighting None Shelf Lighting Additional 1 Row Shelf 0 51 0 51 0 77 59 59 85 Additional 2 Row Shelf Maximum 1 02 1 02 1 54 118 118 170 115V Lighting Circuit Total Standard Lighting Total Optional Lighting Optional Shelf...

Page 5: ...reen BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only 2 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 4 6 Return Air Fans 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND ...

Reviews: