7-9
Coolant Pump
Problem: No coolant flow:
Solution:
1.
Make sure the switch is on.
2.
Check if the pump motor is working.
3.
Check coolant level.
4.
If all the above are normal, change the pump.
8.
Taper Attachment
Installation Taper Attachment:
STEP 1:
Install taper attachment on the carriage using screws No.
○
31
via hole
○
A
(Do not tighten too tight using screw M10x40L and flat washer.)
STEP 2:
Disengaged screw No.
○
8
STEP 3:
Adjust the position of No.
○
1
and let arc gage point is contacted with No.
206009.
STEP 4:
Set a dial gage on the No.
○
19
, and gage point is contacted the surface of
bed. Moving No.
○
19
pointer has to be constant lifting its nut, adjusting the
position of No.
○
1
STEP 5:
Disengage screw No. 206010 then lock No. 206009 to No.
○
7
STEP 6:
Replace screw No.
○
8
STEP 7:
Drill B hole. (Using
Ø6mm drilling tool)
STEP 8:
Set straight pin. (Ø 6 x 45L)
STEP 9:
Install universal connected-rod.
35