background image

1. Apply pipe dope sparingly to both ends of pipe nipple (provided in kit) and install nipple in 1/8-in. tapped opening in gas valve. Finger

tighten. (See Fig. 8.)

2. Apply pipe dope sparingly to threaded end of street elbow (provided in kit) and install elbow on nipple. Finger tighten. Use a small pipe

wrench for final tightening.

3. Point male end of street elbow vertically up. (See Fig. 8.)

4. Install propane low gas pressure switch (provided in kit) on street elbow. After switch has been finger tightened, use small wrench on base

of pressure switch for final tightening. When pressure switch is tight, switch terminals should point as shown in Fig. 8 relative to gas valve
and clear control compartment access door.

5. Apply pipe dope sparingly to end of inlet gas pipe and reconnect pipe to gas valve.

Fig. 3—Redundant Automatic 2-Stage Gas Valve

A99218

ON

O

F

F

ON/OFF
SWITCH

INLET
PRESSURE
TAP

BURNER ENCLOSURE

REFERENCE PRESSURE TAP

(VARIABLE-SPEED, CONDENSING

FURNACES ONLY)

MANIFOLD

PRESSURE

TAP

LOW-FIRE
ADJUSTMENT
ALLEN SCREW
(UNDER CAP)

HIGH-FIRE
ADJUSTMENT
ALLEN SCREW
(UNDER CAP)

PLUG BUTTON
(2-STAGE AND
VARIABLE–SPEED,
NON–CONDENSING
FURNACES ONLY)

Fig. 4—Position of Ignitor to Burner

A93347

BURNER

IGNITOR

11 32

"

7 8

"

C

L

C

L

IGNITOR
ASSEMBLY

CELL
PANEL

BURNER

13 32

"

HOT
SURFACE
IGNITOR
ASSEMBLY

—5—

Summary of Contents for KGANP26012SP

Page 1: ...is conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority having jurisdiction If...

Page 2: ...ra parts INSTALLATION SECTION 1 MODELS 58DXT 58TMA 58TUA 58UHV 58UXT 58UXV 330AAV 330JAV 331AAV 331JAV 333BAV AND 333JAV INDUCED COMBUSTION HOT SURFACE IGNITION 2 SPEED AND VARIABLE SPEED NON CONDENSI...

Page 3: ...anne a Be sure gas and electrical supplies to furnace are off b Remove wires from gas valve Note location for reassembly c Remove wires from flame sensor and flame rollout safety switch es Disconnect...

Page 4: ...pply 13 Remove manometer but do not reinstall gas valve inlet pressure tap plug See Fig 3 PROCEDURE 4 INSTALL LOW GAS PRESSURE SWITCH LGPS NOTE The inlet gas pipe must be disconnected from valve so pr...

Page 5: ...nal tightening When pressure switch is tight switch terminals should point as shown in Fig 8 relative to gas valve and clear control compartment access door 5 Apply pipe dope sparingly to end of inlet...

Page 6: ...main gas and electric supplies to furnace are off 2 Remove 1 8 in pipe plug from manifold pressure tap on downstream side of gas valve See Fig 3 3 Attach manometer to manifold pressure tap on gas val...

Page 7: ...r propane is the same as for natural gas See furnace rating plate for input rate The input rate for propane is determined by manifold pressure and orifice size The gas valve regulator must be set for...

Page 8: ...old pressure tap plug See Fig 3 NOTE Use propane gas resistant pipe dope to prevent gas leaks DO NOT use Teflon tape 7 Turn on furnace power supply 8 Turn furnace gas valve switch to ON position 9 Set...

Page 9: ...de c blage peut tre une source de danger et de panne 7 Remove burner box pressure tube from gas valve burner enclosure reference pressure tap fitting See Fig 11 8 Remove screws that secure manifold to...

Page 10: ...CONTROL CONVERSION LABEL Fig 11 Redundant Automatic 2 Stage Gas Valve A99218 ON O F F ON OFF SWITCH INLET PRESSURE TAP BURNER ENCLOSURE REFERENCE PRESSURE TAP VARIABLE SPEED CONDENSING FURNACES ONLY M...

Page 11: ...egulator fitting 5 Reconnect gas supply pipe to gas valve using backup wrench on gas valve to prevent rotation and improper orientation NOTE Use propane gas resistant pipe dope to prevent gas leaks DO...

Page 12: ...tall gas valve inlet pressure tap plug See Fig 11 NOTE Use propane gas resistant pipe dope to prevent gas leaks DO NOT use Teflon tape PROCEDURE 6 INSTALL LOW GAS PRESSURE SWITCH LGPS A 6 INSTALL LOW...

Page 13: ...nducer housing Add 1 4 in splice connector to this wire 2 Connect uninsulated terminal of 1 orange wire provided in kit to splice connector Connect other end to C terminal on low gas pressure switch L...

Page 14: ...11 32 7 8 C L C L IGNITOR ASSEMBLY IGNITOR ASSEMBLY CELL PANEL BURNER BURNER BOX Fig 17 Adjusting Manifold Pressure Manifold Attachment A94351 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 BURNER ENCLOSURE REMOVE COV...

Page 15: ...ODE RECALL LOW HEAT ONLY BPH BYPASS HUMIDIFIER EMERGENCY HEAT MZ MULTI ZONE COMPONENT TEST HEATING BLOWER OFF TIME DELAY Fig 19 Installation of Low Gas Pressure Switch A99222 OFF STREET ELBOW 1 8 IN N...

Page 16: ...hermostat connections See Fig 18 This keeps furnace locked in high heat operation e Adjust high heat input rate manifold pressure for propane gas See kit rating plate 326108 203 f Turn high heat adjus...

Page 17: ...rners until after hot surface ignitor begins glowing PROCEDURE 11 LABEL APPLICATION NOTE See Fig 10 for label location 1 Fill in Conversion Responsibility Label 326108 204 and apply to blower access p...

Page 18: ...18...

Page 19: ...19...

Page 20: ...2000 CAC BDP P O Box 70 Indianapolis IN 46206 agganp23 20 Book Tab 1 6a 4 8a Catalog No 63GA NP5...

Reviews: