HVFL Unvented Gas Logs
59D1016
19
ROCk WOOL and LOG PLACEMENT
W
ARNING
The positioning of the logs are critical to the safe and clean operation
of this heater. Sooting and other problems may result if the logs are not
properly and firmly positioned in the appliance. Never add additional logs or
embellishments such as pine cones, vermiculite or rock wool to the heater.
Only use the logs and EB-RW (rock wool) supplied with the unit.
Failure to position the parts in accordance with diagrams below or to use
only parts specifically approved for this heater may result in property damage
or personal injury.
Before you begin
— This unit is supplied with four or
five ceramic fiber logs. Do not handle these logs with
your bare hands.
Always wear gloves to prevent
skin irritation from ceramic fibers.
After handling
the logs, wash your hands gently with soap and water
to remove any traces of fibers.
PLACE ROCk WOOL
Starting on the second row of burner ports, place EB-
RW (Rock Wool) in dime-size pieces on the second
row of ports and going toward back of front burner.
NOTE:
Do not put EB-RW (Rock Wool) on first row
of burner ports.
LG953
18 24HVFL rockwool
Figure 25 -
Place Rock Wool
Dime-Size
Rock Wool
First Row of Ports
(Leave Open)
LG953
LG954
HVFL SH back log
Figure 26
Back Log #1
LG954
PLACE SEASONED HARDWOOD LOGS ON
GRATE
1. Place back log (#1) on two pins located near the
back of base. Check log position and stability.
Figure 26
W
ARNING
•
Use only EB-RW provided with log set.
•
Do not add additional rock wool.
•
Place EB-RW (rock wool) on front burner
ports only. DO NOT PLACE EB-RW ON
BACk BURNER!
Pins