HVFL Unvented Gas Logs
8
59D1016
FP2814
18 24 HVFL controls
Piezo Ignitor
Ignitor Pilot
Switch
Hi/Lo Knob
LG814
OPERATING INSTRUCTIONS
MILLIVOLT CONTROL LIGHTING INSTRUCTIONS
1.
STOP!
Read the safety information label.
. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, refer to instructions for
Match Lighting Instructions, Page 26
.
4. Turn gas control knob clockwise
to the OFF position, set thermostat to lowest setting and turn ON/OFF
switch to OFF position.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas,
STOP!
Follow
What to Do if You Smell Gas, Page 27
. If you don't smell gas, go to next step.
6. From OFF position, turn the gas control knob counterclockwise
to IGN position. Push in control
knob for 5 seconds.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shut-
ting off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
to the ON position.
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to
ON position or adjust thermostat to desired setting.
11. If the gas logs will not operate, follow the instructions
To Turn Off Gas To Heater
below and call your
service technician or gas supplier.
TO TURN OFF GAS TO HEATER
1. Turn control knob clockwise
to OFF position to completely shut off the heater.
. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
Pilot
FP75
Millivolt Controls