HVFL Unvented Gas Logs
59D1016
5
PRODUCT FEATURES
GAS PRESSURES
Natural
Propane (LP)
Manual Regulator Pressure 4.0” w.c.
10.0” w.c.
Millivolt Regulator Pressure 3.5” w.c.
10.0” w.c.
Millivolt Pilot Regulator
3.5” w.c.
n/a
Max. Gas Inlet Pressure
10.5” w.c.
13.0” w.c.
Min. Gas Inlet Pressure
5.0" w.c.
11.0" w.c.
GAS SPECIFICATIONS
Max.Input Min. Input
Model
Fuel
Control
BTU/h
BTU/h
18HVFLNM
Nat.
Manual
8,000
18,000
18HVFLPM
LP
Manual
8,000
18,000
18HVFLNV
Nat.
Millivolt
8,000
0,000
18HVFLPV
LP
Millivolt
8,000
0,000
4HVFLNM
Nat.
Manual
36,000
0,000
4HVFLPM
LP
Manual
36,000
4,000
4HVFLNV
Nat.
Millivolt
36,000
4,000
4HVFLPV
LP
Millivolt
36,000
7,000
NOTE:
An external regulator is required to reduce supply
pressure to a maximum of 10.5" w.c. on Natural Gas sys-
tems operating at higher pressure.
NOTE:
An external regulator is required to reduce supply
pressure to a maximum of 13.0" w.c. for LP systems.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the
use of matches or batteries.
Manual control has three (3) positions:
OFF
- All gas to the gas logs is shut off at
the valve.
IGN
- Valve position to light/maintain a
standing pilot.
HI/LOW
- Variable position corresponding to
desired flame height.
Milli-Volt control has four (4) positions:
OFF
- All gas to the gas logs is shut off at
the valve.
IGN
- Valve position to light/maintain a
standing pilot.
ON
- Valve position to turn ON/OFF log
set with remote switch/thermostat.
LOW/HI
- Variable position to control flame
height (heat output).
PILOT/ODS
The gas log heater is fitted with a specially designed
safety pilot (ODS assembly) which senses the amount
of oxygen available in the room and shuts the gas log
heater off if the oxygen level begins to drop below
a satisfactory level. The pilot can only be relit when
adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a milli-volt
(thermopile) generator to provide power for remote
activation.