background image

Damocles2

Ares LTE

9

Sensors

Use this tab to configure basic properties of sensors: 

•  

Del

 – removes the sensor from the list (e.g. when the sensor is disconnected). If the sensor 

remains physically connected, it will be detected again when the Ares LTE unit is restarted. 
Sensor no. 65535 is a system entry and cannot be deleted.

•  

Find Sensors

 – detects all connected sensors. By default, sensors are detected only when the 

unit is powered up. Sensors connected later must be discovered manually. Detected sensors 
are automatically added to the list.  

•  

Delete All Sensors 

– deletes all discovered sensors. System entry Sensor no. 65535 can't be deleted.

• 

Save

 – saves all changes.

SMS

Use this tab to configure alarm text message (SMS) recipients. Each recipient phone number is 
also authorized to request information from Ares 12 LTE by dialing the unit's phone number and 
to send SMS commands without a password (see 

Advanced settings

).

First steps

Summary of Contents for Ares 10 LTE

Page 1: ...Ares 10 12 LTE User manual...

Page 2: ...r adapter or power supply cable are noticeably damaged If the device is used in a manner other than designed for the protection provided by the device may fail The local electrical system must include...

Page 3: ...s 11 General 11 Inputs 13 Outputs 14 Sensors 15 Time 16 SMS 17 SMS template 18 Email 19 Email templ 20 GPRS Internet 21 Portal 22 Logger 24 System 25 Connecting to the Portal 26 How to reduce operatin...

Page 4: ...transfer Data transfer when values differ by more than the specified tolerance Status request SMS from a predefined number SMS from any number containing a password Ringing the device from a predefine...

Page 5: ...sed con tact when the resistance is less than 2 7 kOhm Resis tances between these values are undefined Power Power supply 9 30V 500mA can be connected to the power terminals or the power barrel connec...

Page 6: ...ire UNI Connector RJ11 1 Wire Bus Sensors Ares 10 LTE up to 3 sensors Ares 12 LTE up to 14 sensors Sensor distance Up to 60m Dry contact inputs Port I1 I2 Type Digital Input supports NO NC Dry contact...

Page 7: ...about 5 seconds after pressing Save When starting the device for the first time pay attention to the mobile network connection and signal strength information If the signal is too weak relocate the an...

Page 8: ...ble to connect the External Outputs module via the 1 Wire UNI interface to the Ares 12 LTE device Find Outputs detects external outputs module By default outputs are detected only when the unit is pow...

Page 9: ...ors By default sensors are detected only when the unit is powered up Sensors connected later must be discovered manually Detected sensors are automatically added to the list Delete All Sensors deletes...

Page 10: ...o the recipients from this address Subject subject prefix Useful for adding a keyword to the e mail subject in order to simplify mail filtering Report End of Alarm users will be also informed when an...

Page 11: ...d values Last Sync Time date and time of last time synchronization over the internet Useful for chec king if the time synchronization works Modem status information about the current modem status and...

Page 12: ...n 50 we strongly suggest to relocate the antenna or use a different mobile carrier Reg Operator regional GSM carrier Indicates a successful connection to the GSM network and the actual carrier when ro...

Page 13: ...tate when the input is Off contact open Name 1 name of the state when the input is On contact closed Alarm Alert specifies when the input is in alarm Disable alarm is disabled for this input Active if...

Page 14: ...ocols On if any alarm the output switches On when at least one of the inputs or sensors is in alarm status Note that this condition reflects the DELAY and HYSTERESIS settings for indi vidual active in...

Page 15: ...il Templ alarm message template See the Email Templ tabs SMS sends a text message SMS when the sensor is in alarm SMS Templ alarm message template See the SMS Templ tabs Serial Code unique 1 Wire ID D...

Page 16: ...rt ntp org bin view Servers NTPPoolServers and http www pool ntp org Time Zone time zone where Ares LTE is used Sync Period indicates how often to synchronize time over the internet 1h 24h Daylight Sa...

Page 17: ...nutes Template template to use for the reminder message Status SMS Settings Ares LTE can send a text message with the current sensor states as a reply to an incoming STATUS message If the phone number...

Page 18: ...idity alarm messages or to define the contents of status and reminder messages Template selects the template to edit Text message contents with macros as variables Preview displays a dialog with a pre...

Page 19: ...authentication to the SMTP server Password password for authentication to the SMTP server Secure Connection SSL No STARTTLS enables encrypted authentication Outgoing Email Address sender e mail addre...

Page 20: ...status and reminder messages Template selects the template to edit Subject subject of the e mail Macros can be used Body message contents with macros as variables Help list of supported macros list o...

Page 21: ...of the Ares LTE unit or the department responsible for managing it Enable GPRS Internet enables internet based services such as sending e mail portal servi ces and time synchronization In case the ser...

Page 22: ...default 80 Username username for authentication to the portal PUSH Password password for authentication to the portal Portal Message messages from remote portal Manual Push manual transmission for tes...

Page 23: ...duces Push Period period of sending values to portal in seconds Log Period period of logging in seconds All values will be sended to portal in one package according of setting Push Period Memory is fo...

Page 24: ...nce of the e mail message Useful for mail filtering in e mail clients Template e mail template selection Default 1 e mail 2 e mail 3 e mail 4 e mail Erase Log after Email deletes recorded values after...

Page 25: ...e configuration file URL Check for FW Version if the URL of the config file is specified checks for the availability of a firmware upgrade GSM Upgrade upgrades the firmware over GSM GPRS Correct addre...

Page 26: ...p right corner of the window then go to Portal tab 2 3 Tick the Enable Portal option and save the changes using the Save button in the bottom right corner of the window Then click the Manual Push butt...

Page 27: ...ly assigned to your account If you do not have a SensDesk account yet click the Register and a registration form will be shown 4 Enter the login details for your new account and a correct e mail addre...

Page 28: ...the Devices View page At this moment the data sending period is set to 10 seconds to show the sensors functionality This page is active only for approximately 15 minutes after the activation then the...

Page 29: ...ason it is different to the login password PUSH password can be used in devices to skip the logging procedure during assigning the device to your portal account or in mobile applications 7 8 Portal fu...

Page 30: ...s 1234 is the default password You have to use it if your number is not listed as one of the 5 SMS recipients In case you are not using the default password it has to be only one word password cannot...

Page 31: ...the information in the Modem Status field on the General tab SIM unplugged no SIM was found Insert a SIM or clean its contact pads Modem initializing modem is being initialized This information should...

Page 32: ...l memory for storing measured values The available recording time depends on the number of values being stored One value takes up 12 bytes of memory Therefore 2048kB 1024 2 097 152B 12B approximately...

Page 33: ...measured value SRC_STATUS Sensors Invalid Normal Alarm Out Of Range Digital inputs Normal Alarm SRC_MIN Lower limit of the Safe Range SRC_MAX Upper limit of the Safe Range SRC_ALARM Alarm begin end Se...

Page 34: ...Ares LTE 34 Mechanical parameters Identical for Ares 10 LTE Mechanical parameters 76 mm 92 2 mm 106 mm 120 mm 36 3 mm 31 mm...

Page 35: ...and industry Poseidon2 3468 Remote monitoring of temperature humidity and other enviromental conditions in industrial design HWg PWR 3 12 25 Measures power consumption using external M Bus meters Pos...

Page 36: ...HW group s r o Formansk 296 Prague 149 00 Czech Republic Phone 420 222 511 918 Fax 420 222 513 833 www HW group com...