background image

Poseidon2 3468 

– Manual 

HW group 

 

 

www.HW-group.com 

14   

 

PosDamIO  

Poseidon Damocles I/O is a command-line utility for Windows and Linux that lets 
you control Poseidon and Damocles units over the XML interface. It can display the 
states of sensors, inputs and outputs, as well as set an output high or low. 

 

 

SensDesk.com 

Online portal for collecting data from LAN and GSM sensors.  
 
Poseidon2 can connect to the SensDesk internet service. All devices can be managed from a single 
WWW interface. Watch sensor states, display your devices in a map, compare trends in time and 
analyze alarm messages.  

 

SensDesk is a way to implement fully functional monitoring of customer technology in a matter of 
minutes, with fixed costs of the system. No need for installing a complex system or adding another 
server at the customer side. 

 

 

 

  Overview of all sensors at a single place 

  Centralized alarm configuration for individual sensors 

  Mobile application for monitoring 

  Remote configuration of GSM devices.  

 

www.SensDesk.com

  

 

Summary of Contents for Poseidon2 3468

Page 1: ...Poseidon2 3468 MANUAL...

Page 2: ...Poseidon2 3468 Manual HW group www HW group com 2...

Page 3: ...wing conditions The device is noticeably damaged The device does not function properly Unfastened parts can move inside the device The device has been exposed to moisture or rain The device has been s...

Page 4: ...Poseidon2 3468 Manual HW group www HW group com 4...

Page 5: ...properly the LINK LED lights up after a short while and then flashes whenever data are transferred activity indication 2 Configuring the IP address UDP Config UDP Config utility root directory of the...

Page 6: ...name optional Click the Apply Changes button to save the settings Alternatively you may use the following utilities to configure the IP address UDP Config for Linux Important To reset the device to f...

Page 7: ...iew of current readings General Setup IP address DNS security username password SNMP SNMP SNMP Trap configuration ports and alarm recipients E mail Configuration and test GSM RFID Configuration and te...

Page 8: ...he device is in the Alarm state For example every 15 minutes NOTE Configuration changes must be confirmed by clicking the Apply Changes button Sends a test e mail and shows the connection log 1 Correc...

Page 9: ...oseidon2 3468 Manual HW group www HW group com 9 GSM Log Time IP address of HWg SMS GW to use for sending text messages SMS Press to synchronize the time with the specified server Recipients phone no...

Page 10: ...connected sensors and displays detected sensors Sends an E mail if the Safe Range for this sensor is exceeded To avoid numerous false alerts by e mail or SMS whenever the reading fluctuates around th...

Page 11: ...inputs Inputs NOTE Configuration changes must be confirmed by clicking the Apply Changes button Poseidon family manual For a detailed description of all settings and tabs see the Poseidon family manu...

Page 12: ...rolled remotely o On if any alarm The output is active if at least one input or sensor is in alarm o On if value equal to Trigger The output is active if the selected sensor reading is equal to the Ta...

Page 13: ...Free HWg PDMS version for 3 sensors Paid versions for 8 20 200 unlimited sensors HWg Trigger Windows application for detecting and reacting to events Detects for instance disconnected devices failed...

Page 14: ...the SensDesk internet service All devices can be managed from a single WWW interface Watch sensor states display your devices in a map compare trends in time and analyze alarm messages SensDesk is a...

Page 15: ...nual HW group www HW group com 15 Mechanical dimensions Power output Poseidon2 3468 features the PWR OUT terminals for powering connected sensors and detectors Powered by 9 30V PWR OUT 9 30V Powered b...

Page 16: ...tate Power up state no state restart memory POWER input Type You can power the device from power input 1 or 2 Power input 1 POWER 9 30V DC 2 5W Jack 9 30V DC barrel inner 2 5 mm outer 6 3 mm Terminal...

Page 17: ...ly isolated from the rest of the device ID range Outputs use ID addresses from 151 to 180 Digital dry contact inputs Digital input terminals may be connected to voltage free contacts or the GND pin Th...

Page 18: ...rs can take advantage of the HWg SDK Software Development Kit with an ActiveX interface and ready made examples VB Visual Basic 6 0 3xx examples Borland C 1xx examples Microsoft Visual C 2xx examples...

Page 19: ...firmware over RS 232 Firmware in the HWg format is available at our website or on the supplied CD Restoring factory defaults To restore the factory default configuration including deleting all passwo...

Page 20: ...Poseidon2 3468 Manual HW group www HW group com 20 Contact HW group s r o Rumunsk 26 122 Praha 2 120 00 Czech republic Tel 420 222 511 918 Fax 420 222 513 833 http www HW group com...