Page 10 of 20 pages
I
nstallatIon
In general
Congratulations on your new HWAM woodburning stove. We are pleased that you have chosen a HWAM
woodburning stove and confident that it will give you much pleasure. To ensure optimum operation and
safety, we recommend that the installation should be carried out by an authorised HWAM retailer or
a fitter recommended by the retailer. For an overview of HWAM retailers, visit www.hwam.com under
“Retailer locations”.
Safety
The installation of your HWAM woodburning stove must always comply with all European, national and
local building regulations. The installation must be carried out in accordance with the instructions in the
installation and user manuals and subsequently registered with the local authorities. Upon installation,
the chimney sweep must approve the installation before you can start using the woodburning stove. All
HWAM woodburning stove packaging material must be handled in accordance with local waste manage-
ment regulations.
Room requirements
Always ensure a supply of fresh combustion air to the room where the stove is to be installed. The
woodburning stove uses approx. 7-23 m
3
of air per hour. A window that can be opened or an adjustable
air valve will be sufficient. It must not be possible to block the adjustable air valve/grate. In newly built/
airtight dwellings, we recommend that a fresh air system should be installed for the direct supply of
external air to the combustion. This fresh-air system may be bought separately.
Before installing the stove, you must ensure that the load-bearing capacity of the floor can withstand
the weight of the stove and the chimney. The weight of the chimney should be calculated according to
its dimensions and height.
Technical measures and data
Test results from nominal test EN 13240
Nominal heating effect
4,7 kW
Flue gas temperature EN 13240 measurement point
193ºC
Flue gas temperature measured in the outlet socket
232ºC
Exhaust gas flow
5,3 g/s
Efficiency
82 %
Annual efficiency
72 %
PM
24 mg/m
3
OGC
65 mg/m
3
NOx
92 mg/m
3
CO at 13% O
2
1125 mg/m
3
CO at 13% O
2
0,09 %
Energy efficiency index
109
Energy efficiency class
A+
Test result based on NS 3058
Particle emissions
4,81 g/kg
The declaration of performance (DoP) can be downloaded from our website, www.hwam.com.
E
nglIsh
Summary of Contents for 4110
Page 1: ...User s Manual EN AUTOPILOT 15 09 2020 97 9706 www hwam com 4110 4120 4150 4140 4130 4160 4240 ...
Page 2: ......
Page 5: ...Page 5 of 20 pages E1 ...
Page 6: ...Page 6 of 20 pages E2 ...
Page 7: ...Page 7 of 20 pages E3 ...
Page 9: ...Page 9 of 20 pages H ...
Page 20: ...www hwam com ...