Page 11 of 20 pages
Model
Weight
Height
Width
Depth
HWAM 4110 / HWAM 4120
135 kg
102,7 cm
51,0 cm
51,0 cm
HWAM 4130 / HWAM 4140
145 kg
119,3 cm
51,0 cm
51,0 cm
HWAM 4150 / HWAM 4160
170 kg
162,1 cm
51,0 cm
51,0 cm
HWAM 4240
140 kg
112,4 cm
54,3 cm
45.5 cm
HWAM 4240 with natural stone cladding
191 kg
116,6 cm
54,3 cm
45,5 cm
HWAM 4240 with soapstone cladding
215 kg
116,6 cm
54,3 cm
45,5 cm
Heat storing slabs HWAM 4150/4160
30/60/90 kg
Floor plate
European, national and local regulations must be observed in terms of the size and thickness of a non-
combustible floor covering the floor in front of the combustion chamber opening. Ask your HWAM
retailer for assistance. The combustion chamber opening is 28.4 cm wide.
Distance to inflammable materials
Your HWAM woodburning stove should always be installed on a non-combustible hearth. If it is installed
on a wooden floor or similar, the floor must be covered with a non-combustible material.
Min. distances - uninsulated flue gas pipe
(drawing A)
HWAM 4110
HWAM 4130
HWAM 4150
HWAM 4120
HWAM 4140
HWAM 4160
HWAM 4240
1.
Recommended for brick wall
10 cm
10 cm
10 cm
1.
For inflammable back wall
15 cm
10 cm
10 cm
2.
For inflammable side wall
42 cm
42 cm
42 cm
1.
To inflammable wall,corner installation,
45º
10 cm
10 cm
10 cm
3.
Distance to furnishings in front
110 cm
90 cm
90 cm
Min. distances - insulated flue gas pipe
(drawing A)
HWAM 4110
HWAM 4130
HWAM 4150
HWAM 4120
HWAM 4140
HWAM 4160
HWAM 4240
1.
Recommended for brick wall
10 cm
Nicht getestet Nicht getestet
1.
For inflammable back wall
10 cm
Nicht getestet Nicht getestet
2.
For inflammable side wall
42 cm
Nicht getestet Nicht getestet
1.
To inflammable wall,corner installation,
45º
Nicht getestet Nicht getestet Nicht getestet
3.
Distance to furnishings in front
110 cm
Nicht getestet Nicht getestet
Remember to pay attention to applicable regulations concerning the required distance
between the wall and smoke pipe.
The distance to a brick wall is set to faciliate the servicing of the HWAM
®
Autopilot™ system.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a flammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The height of the chimney must ensure sufficient draught and prevent any smoke nuisance. As a general
rule, satisfactory draught conditions are achieved if the chimney is 4 m above the stove and at least 80
Summary of Contents for 4110
Page 1: ...User s Manual EN AUTOPILOT 15 09 2020 97 9706 www hwam com 4110 4120 4150 4140 4130 4160 4240 ...
Page 2: ......
Page 5: ...Page 5 of 20 pages E1 ...
Page 6: ...Page 6 of 20 pages E2 ...
Page 7: ...Page 7 of 20 pages E3 ...
Page 9: ...Page 9 of 20 pages H ...
Page 20: ...www hwam com ...