background image

13

Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes 
be treated as a flammable wall, in which case we ask you to contact your local chimney sweep or glass 
producer to hear at what distance the stove should be kept from glass.

Requirements for chimney and smoke pipe

The chimney must be of a sufficient height to enable an adequate draft and to prevent smoke problems. The 
stove requires a draft of at least 12 Pa. The chimney must have a minimum opening equivalent to Ø 15 cm.  
The chimney opening should always be at least the size of the outlet socket of the stove. The chimney must 
have an easily accessible soot door. Smoke pipe and chimney must always be suitable for a stove connec-
tion.  Ask your HWAM dealer for more information.

Changing the smoke outlet from top outlet to rear outlet - HWAM 4510/4520/4530/4540 
(Drawing F) 

1.  Lift the top plate (2) off the stove.
2.  Remove the rear plate (3) by loosening the two screws (4). The rear plate has a cut-out for the flue 

pipe. Cut out the plate (5) within this cut-out.

3.  The heat shield has a cut-out for the flue pipe. Cut out the plate (6) within this cut-out.
4.  Remove the cover plate (7) on the rear of the stove (behind the cut-out plate in the heat shield) by 

removing the three screws (8).

5.  Remove the smoke ring (9) above the combustion chamber by removing the three screws (10).
6.  Place the smoke ring (9) in front of the flue outlet hole on the rear of the stove and affix using the 

three screws (10).

7.  Place the cover plate (7) so that it closes the flue outlet on top of the combustion chamber (where 

the smoke ring was just removed) and affix using the three screws (8).

8.  Place the rear plate (3) on the guide taps (11) on the rear side of the stove's base plate and affix the 

rear plate using the two top screws (4).

9.  Lie the top plate (2) on the stove.
10.  Place the cast-iron or stone top cover (12) in the hole in the top plate.

Changing the smoke outlet from top outlet to rear outlet - HWAM 4550/4560 (Drawing F)

1.  Remove the heat storage compartment front (1) by lifting the front and pulling away from the stove.
2.  Lift the top plate (2) off the stove.
3.  Remove the rear plate (3) by loosening the two screws (4). The rear plate has a cut-out for the flue 

pipe. Cut out the plate (5) within this cut-out.

4.  The heat shield has a cut-out for the flue pipe. Cut out the plate (6) within this cut-out.
5.  Remove the cover plate (7) on the rear of the stove (behind the cut-out plate in the heat shield) by 

removing the three screws (8).

6.  Open the metallic tabs (13) and take the wires out.
7.  Disassemble the lambda sensor coupling (14a+14b) and pull its upper part free from the wire fastener 

(15).

8.  Remove the temperature monitor (16) from the smoke ring (9) and then pull it out of the hole (17) 

at the rear end of the heat storage compartment.

9.  Remove the smoke ring (9) above the combustion chamber by removing the three screws (10). 

Remove the smoke ring (9) through the front opening of the heat storage compartment and then 
pull the lambda sensor, including the topmost part of the wire, through the hole (17) at the rear end 
of the heat storage compartment.

10.  Place the smoke ring (9) in front of the flue outlet hole on the rear of the stove and affix using the 

three screws (10).

11.  Reattach the temperature monitor (16) in the smoke ring, leading the sensor about 3 cm into the 

smoke ring.

12.  Assemble the lambda sensor (14a+14b) and fit it back into the wire fastener (15).
13.  Fix the two wires by closing the metallic tabs (13) again.

Summary of Contents for 4510

Page 1: ...User s Manual EN 05 09 2017 97 9688 www hwam com 4530 4550 4560 4540 4520 4510 ...

Page 2: ......

Page 3: ...ish Drawings 4 8 HWAM Autopilot IHSTM 9 For UK The Clean Air Act 1993 and Smoke Control Areas 10 Installation 11 Firing manual wood 16 Firing in general 19 Maintenance 20 Operational problems 21 Declaration of Performance 21 ...

Page 4: ...4 A1 1 2 3 4 3 4 1 A2 B A ...

Page 5: ...5 C 1 2 3 5 4 6 6 7 8 9 11 12 10 C1 C2 4 6 6 7 14 13 3 9 10 E ...

Page 6: ...6 F ...

Page 7: ...7 F ...

Page 8: ...8 F ...

Page 9: ...combus tion as well as a good fuel economy regardless of external conditions such as the type of firewood used the chimney the user s experience and other external circumstances The HWAM Autopilot IHSTM consists of the following components Air box the Air box contains a printed circuit board software as well as three motors that control primary secondary and tertiary combustion air The fresh air s...

Page 10: ...Air Act can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The HWAM 4500 IHS stoves detailed below have been recommended as suitable for use in smoke control areas when burning wood logs ...

Page 11: ...stove Model Weight Height Width Depth HWAM 4510c 4510m 99 97 kg 75 5 cm 50 0 cm 40 6 cm HWAM 4510c 4510m with low plinth 105 103 kg 93 0 cm 50 0 cm 40 6 cm HWAM 4510c 4510m with high plinth 109 107 kg 104 0 cm 50 0 cm 40 6 cm HWAM 4520c 4520m 94 92 kg 75 5 cm 50 0 cm 40 6 cm HWAM 4520c 4520m with low plinth 100 98 kg 93 0 cm 50 0 cm 40 6 cm HWAM 4520c 4520m with high plinth 104 102 kg 104 0 cm 50 ...

Page 12: ... combustible constructional hearth The non combustible constructional hearth must extend 425 mm in front of the appliance It is still considered a combustible floor even if an ember catch ing non combustible floor plate is placed on top of the combustible floor Floor in front exceed 100 C demand closer than 425 mm in front of the stove installed without a plinth Floor directly beneath the stove in...

Page 13: ...sing the three screws 8 8 Place the rear plate 3 on the guide taps 11 on the rear side of the stove s base plate and affix the rear plate using the two top screws 4 9 Lie the top plate 2 on the stove 10 Place the cast iron or stone top cover 12 in the hole in the top plate Changing the smoke outlet from top outlet to rear outlet HWAM 4550 4560 Drawing F 1 Remove the heat storage compartment front ...

Page 14: ...ore you start using the stove 4 Rear flue outlet Closed at the factory using a plate affixed with screws The flue outlet is thus concealed behind the rear plate 5 Removable rear plate Must always be installed if the stove is next to a flammable wall 6 Loose heat shield under the ash pan Adjustment feet The stove comes with four adjustment feet Mount and adjust the adjustable feet screws in accorda...

Page 15: ...window pane soot free and sucks air into the combustion via the HWAM Autopilot IHSTM The chimney draft is created by the differences in temperature inside and outside the chimney The higher the temperature within the chimney the greater the draft a brick chimney takes longer to warm up than a steel chimney On days where the weather and wind conditions create insufficient draught inside the chimney...

Page 16: ... rubbish such as milk cartons lacquered wood or impregnated wood or fossil fuels The reason that you should not apply any of the above is that during combustion they develop substances that are health hazardous and harmful to the environment These substances could also damage your wood burning stove and chimney rendering the product warranty void Storage of wood The wood s water content of a maxim...

Page 17: ...perature sensor emit a stoking alarm even if there is still unburned wood and flames in the combustion chamber The stoking alarm is emitted to make you aware that the fire needs more energy Restoking with small pieces of kindling wood can often provide a more rapid and sufficient temperature rise HWAM Autopilot IHSTM closes all three air dampers when the stove is in standby mode This prevents hot ...

Page 18: ...arge amount of wood 700 1200 g 1000 1800 g 1600 2300 g In terms of combustion technique you should always stoke the stove with at least two pieces of wood at a time even if you only use a small amount of wood You can also choose not to restoke After a while the stove will then automatically go into hibernation Important Never leave a stove before there are lasting flames in the wood after re stoki...

Page 19: ...riations in external circumstances Nevertheless it is important to use clean and dry wood humidity approx 16 18 Read more on www hwam com Cleaning the glass We recommend wiping the glass after a fire This is best done using a paper towel Types of fuel The stove may be damaged by very high temperatures and the glass may turn white for example This can be avoided by never allowing the stove to burn ...

Page 20: ...eaning Drawing E Lift the smoke shelf 1 out of the combustion chamber Unhook each half of the smoke guide plate 2 from the hook 3 under the top plate Ashes It is easiest to empty the ash pan by pulling a plastic bag over it turning it upside down and then carefully removing it from the bag Ashes are disposed of via the domestic waste collection Please note that there may be embers in the ashes for...

Page 21: ...tion on chimney or contact chimney sweep Soot door leaking or dislodged Replace or refit Never open the door when there are still flames on the wood Uncontrollable combustion Faulty seal in door Fit new seal Safety Alarms In case the safety alarms go off you must not use the stove Contact your dealer as soon as possible At interruptions that you cannot yourself rectify you should contact the deale...