15
Surface
The surface does not normally require any treatment. Any damage to the coating may be remedied using
a Senotherm spray.
Guarantee
The guarantee does not cover damage due to insufficient maintenance!
o
pEratIonal
problEms
Blackened glass
• The wood is too damp. Only use wood stored for at least 12 months under cover and with a moisture
level not exceeding 20%.
• The doors seals may be not be tight.
• Insufficient secondary air introduced to the pane-flushing system. Push the adjustment bar further to
the right until the glass is burned clean.
• Intermittent firing. Allow the insert to heat through properly.
Smoke in the room when opening door
• The damper in the chimney may be closed. Open the damper.
• Insufficient chimney draft. See section on chimney or contact chimney sweep.
• Soot door leaking or dislodged. Replace or refit.
• Never open door when there are still flames in the wood.
Uncontrollable combustion
• A seal in the door is not completely tight. Replace the seal.
• If the draught is too strong inside the chimney, it may be necessary to set the adjustment bar to mini-
mum, i.e. to the left.
If problems occur that you cannot fix yourself, please consult your wood-burning stove
dealer.
Summary of Contents for 55s
Page 2: ......
Page 4: ...1 1 1 A1 A2 A3 7 8 5 6 5 4 3 2 a 39 1 cm b 40 4 cm 1 2...
Page 5: ...D C 3 2 1 B 1 1 1 6 5 4...
Page 6: ...E F G 1 1 1 2 2 H...
Page 57: ...57...
Page 58: ...58...
Page 59: ......
Page 60: ...hwam hwam com www hwam com...