8
It is possible to connect several devices to the same chimney. However, it is important to first check the
applicable rules. Contact your local chimney sweeper for the approval of your chimney.
Even a good chimney can function badly if it is not used correctly. Similarly, a bad chimney may function
well if it is used correctly.
Chimney sweeping
To prevent the risk of chimney fires, the chimney must be cleaned every year. The flue duct and the smoke
chamber above the baffle plate must be cleaned together with the chimney. If the chimney’s height makes
cleaning from above impossible, a cleaning hatch must be installed in the chimney.
In case of a chimney fire, close all dampers and call the firefighters. Before any further use, have the
chimney checked by the chimney sweeper.
Test results from nominal test EN 1229:
Nominal heating effect
6.0 kW
Smoke temperature
259°C
Exhaust gas flow
6.5 g/sec.
m
ountIng
and
connEctIon
(d
rawIng
a)
The HWAM I 0/55 consists of a moveable, external brickwork casing, as well as an insert that is pushed
into place and connected once the brickwork casing has been assembled.
The HWAM I 30/55 can be connected in two ways:
1. Mounting and connecting in an existing fireplace.
2. New construction around the insert, possibly including heat ducts to other rooms.
1. Mounting and connecting in an existing fireplace (Drawing A1-A3).
Before mounting the insert in a brick-built fireplace, the regulating damper in the existing chimney must
be removed and the smoke neck, if any, should be widened so that the fire tube from the insert can be
connected directly to the chimney. Any bricks positioned on edge at the bottom of the fireplace should
also be removed.
In advance, decide with a specialist or the chimney sweep where a soot door
(1)
should be placed, so
that the fire tube can be cleaned from above while the door of the insert remains closed.
Mounting the smoke pipe (Drawing A1)
First mount the joining flange
(2)
with a suitable length of fire tubing or flexible tubing
(3)
. Push the
inner pipe into the connector. The inner pipe must be turned so that the handle goes as far as possible
into the connector.
Trim approximately fireproof batts of 50 mm each
(4)
so that they fit tightly into the chimney space
and cut a hole in the centre to fit tightly around the tube.
Place the fire tube in the chimney so that the joining flange corresponds to the given measurements.
a. Distance from front edge of the brick hole, if the insert must be flush with the brickwork.
b. Height over the bottom of the insert.
Summary of Contents for 55s
Page 2: ......
Page 4: ...1 1 1 A1 A2 A3 7 8 5 6 5 4 3 2 a 39 1 cm b 40 4 cm 1 2...
Page 5: ...D C 3 2 1 B 1 1 1 6 5 4...
Page 6: ...E F G 1 1 1 2 2 H...
Page 57: ...57...
Page 58: ...58...
Page 59: ......
Page 60: ...hwam hwam com www hwam com...