47
i
nStAllAtion
General information
Installation of your HWAM woodburning stove must always comply with local building regulations. It
is a good idea to consult your local chimney sweep before installing, since he will be the one to sweep
the chimney and stove.
Always follow the instructions of the manual carefully and make sure that the installation is carried
out by a qualified professional. HWAM packaging material should always be handled in accordance
with the local rules for waste handling.
Room requirements
There must be a constant supply of fresh air to the room in which the stove is to be installed. A window
that opens or an adjustable air vent should be sufficient, but it is also possible to connect the stove to a
HWAM combustion air system. The air inlet/grating must be placed so that they do not become blocked.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a flammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
Load-bearing capacity of floor
Before installing the stove, you must ensure that the load-bearing capacity of the floor can withstand the weight of
the stove and the chimney. The weight of the chimney should be calculated according to its dimensions and height.
Technical data
Model
Weight
Height
Width
Dept
HWAM 3120
104 kg
100,5 cm
47,9 cm
41,4 cm
HWAM 3120
w. soapstone top plate
114 kg
100,5 cm
47,9 cm
41,4 cm
The stove is mainly made of sheet iron, with some items made of cast iron. The HWAM Autopilot
IHS
TM
is an electronic product primarily consisting of plastic, a printed circuit board and wires.
Test results from nominal test EN 13240
Nominal heating effect
4.5 kW
Smoke temperature
238ºC
Exhaust gas flow
3,66 g/s
Efficiency
83,4%
Distance to inflammable materials
Your HWAM woodburning stove should always be installed on a non-combustible hearth. If it is
installed on a wooden floor or similar, the floor must be covered with a non-combustible material.
HWAM 3120 (Drawing A)
1.
Recommended for brick wall
10 cm
1.
For inflammable back wall
10 cm
2.
For inflammable side wall
20 cm
1.
To inflammable wall,corner installation
13 cm
3.
Distance to furnishings in front
80 cm
Remember to pay attention to any regulations concerning the required distance between
the wall and smoke pipe.
Summary of Contents for Autopilot IHS 3120
Page 1: ......
Page 2: ...2 ...
Page 4: ...4 ...
Page 5: ......
Page 6: ...6 F E 1 6 6 7 4 5 9 8 2 3 6 2 1 3 4 5 ...
Page 7: ...7 G ...
Page 8: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 20: ...20 ...
Page 21: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 34: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 46: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 58: ...58 ...
Page 59: ...59 ...
Page 60: ......