48
Requirements for chimney and smoke pipe
The chimney must be of a sufficient height to enable an adequate draft and to prevent smoke problems.
The stove requires a draft of at least 12 Pa.
The chimney must have a minimum opening equivalent to Ø 150 mm. The chimney opening should
always be at least the size of the outlet socket of the stove. The chimney must have an easily acces-
sible soot door.
Smoke pipe and chimney must always be suitable for a stove connection. Ask your HWAM dealer for
more information.
The smoke pipe and the chimney must always be suitable for wood-burning stoves and certified for
temperatures up to 600o Celsius. Ask your HWAM dealer for more information.
Connection to chimney
All the stoves have both rear and top smoke outlet that can be connected to an approved steel chimney
on top or directly out at the rear to a chimney.
Make sure that the chimney is tight and that no false draft is caused around neither the cover plate,
in connection with a covered smoke outlet, nor the cleanout door and pipe connections. Please note
that bent and/or horizontal smoke pipes will reduce the effect of the chimney draft.
Vertical cross-section of smoke flue (Drawing B and C)
B: Top smoke outlet
C: Rear smoke outlet
• Steel chimney (9).
• Flue gas elbow (10). Fits into smoke flue socket.
•
Brick-built jamb of flue (11).
• Built-in pipe sleeve (12). Fits smoke flue.
•
Wall rosette (13). Covers disruption to wall around pipe sleeve.
•
Joint (14). Sealed with packing material.
• Smoke outlets (15) of the HWAM stove.
•
Smoke flue regulating damper (16).
•
Soot door (17).
Fitting the loose parts
Before the stove is installed, you must ensure that all loose parts are fitted correctly.
Vertical cross-section of the stoves (Drawing B):
• The smoke shelf (5). To be placed on top of the steel rail and on the holders in the sides.
• Two-piece smoke defector plate (6). Each half is hung on the hooks located beneath the top plate. The
two halves join in the holders behind the air pipe. Once the stove has been installed, twist the protection
off the two hooks by using pliers or a screwdriver.
• Cover plate (7). Should always cover the grate.
• Loose heat shield (8) under the ash pan. This can be used as a lid when the ash pan is removed for
emptying.
Summary of Contents for Autopilot IHS 3120
Page 1: ......
Page 2: ...2 ...
Page 4: ...4 ...
Page 5: ......
Page 6: ...6 F E 1 6 6 7 4 5 9 8 2 3 6 2 1 3 4 5 ...
Page 7: ...7 G ...
Page 8: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 20: ...20 ...
Page 21: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 34: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 46: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 58: ...58 ...
Page 59: ...59 ...
Page 60: ......