29
Control options
Manual: Variable rotary gas control with integrated Piezo Ignition, Permanent pilot facility and
fl ame failure safety device
Remote: Integrated Ignition, Permanent pilot facility and fl ame failure safety device, battery
operated hand held.
Technical information
English
Carmen, Balanced Flue
Carmen, Natural Draught
Natural
LPG
Gas
I2H
I2L
I2E/12E+
I2ELL
LPG I3P
G20 G25 G20 G25 G25 G31
Heat Input (gross)
7.7 kW
7.3 kW
7.7 kW
7.3 kW
6.3 kW
6.2 kW
Supply pressure
20 mbar
25 mbar
20 mbar
25 mbar
20 mbar
37 mbar
Burner pressure
17.9 mbar
22.1 mbar 17.9 mbar
22.1 mbar
17.9 mbar
36.6 mbar
Gas rate
0.73 m
3
/hr 0.80
m
3
/hr 0.73
m
3
/hr 0.80
m
3
/hr 0.70
m
3
/hr 0.23
m
3
/hr
Injector marking
560
560
560
560
200
Country of use
DK, AT, FI,
NL
BE & FR
DE
BE, FR,
IT, IE, PT,
IE, IT, PT
ES, SE & GB
ES & GB
Natural
LPG
Gas
I2H
I2L
I2E/12E+
I2ELL
LPG I3P
G20 G25 G20 G25 G25 G31
Heat Input (gross)
8.3 kW
7.7 kW
8.3 kW
7.7 kW
7.0 kW
6.8 kW
Supply pressure
20 mbar
25 mbar
20 mbar
25 mbar
20 mbar
37 mbar
Burner pressure
17.9 mbar
22.1 mbar 17.9 mbar
22.1 mbar
17.9 mbar
36.6 mbar
Gas rate
0.80 m
3
/hr 0.86
m
3
/hr 0.80
m
3
/hr 0.86
m
3
/hr 0.78
m
3
/hr 0.25
m
3
/hr
Injector marking
560
560
560
560
200
Country of use
DK, AT, FI,
NL
BE & FR
DE
BE, FR,
IT, IE, PT,
IE, IT, PT
ES, SE & GB
ES & GB
Summary of Contents for Carmen gas
Page 2: ...2...
Page 4: ...4 650 A A 186 1077 869 462 532 A A 650 A A 182 850 686 442 528 A A Figaro gas Carmen gas A B...
Page 6: ...6 G A E B C F F J H I D F K L G A H I D K F J a b E F...
Page 7: ...7 G G1 G4 G5 G6 G7 G8 G9 G10 G11 G2 G3...
Page 8: ...8 H H1 H2 H3 H4 H5...
Page 50: ...50...
Page 51: ...51...