If .the .insert .is .to .be .mounted .in .a .newly .built, .non-approved .open .fireplace, .all .legal .requirements .and .
local .building .regulations .must .be .observed . .It .would .always .be .advantageous .to .consult .your .chimney .
sweep .before .mounting .the .insert . .
Room requirements
There .must .be .a .constant .supply .of .fresh .air .to .the .room .in .which .the .insert .is .to .be .installed . .A .window .
that .opens .or .an .adjustable .air .vent .should .suffice .
Please .be .aware .that .not .all .glass .parts .are .heat-resistant . .For .this .reason, .a .glass .wall .should .sometimes .
be .treated .as .a .flammable .wall, .in .which .case .we .ask .you .to .contact .your .local .chimney .sweep .or .glass .
producer .to .hear .at .what .distance .the .insert .should .be .kept .from .glass .
Distance to inflammable materials
Please .refer .to .local .building .regulations .to .determine .the .size .of .the .fireproof .area .in .front .of .the .fireplace . .
The .insert .must .be .positioned .at .least .30 .cm .above .the .floor .if .the .floor .is .made .of .flammable .material .
If .there .is .inflammable .material .around .the .outer .casing, .non-inflammable .insulation .(Fire .Batts) .is .required .
between .the .casing .and .the .inflammable .material . .The .insulation .must .be .60 .mm .thick .on .both .sides .of .
and .behind .the .casing .and .40 .mm .thick .beneath .the .bottom .of .the .casing . .The .requirement .for .insulation .
above .the .top .of .the .casing .is .140 .mm . .The .thermal .conductivity .of .the .insulation .must .be .less .than .0 .09 .
W/m .x .K .(as .measured .at .200 .ºC); .i .e ., .thermal .conductivity .must .be .lower .than .0 .09 .W/m .x .K . . .
Chimney requirements
The .chimney .must .be .of .a .sufficient .height .to .enable .an .adequate .draft .and .to .prevent .smoke .problems . .
Nominal .draft: .approx . .12 .Pa .
The .chimney .must .have .a .minimum .opening .equivalent .to .Ø .150 .mm . .
The .chimney .opening .should .always .be .at .least .the .size .of .the .outlet .socket .of .the .insert . .
The .chimney .must .have .an .easily .accessible .soot .door .
Chimney
The .chimney .is .the .“motor” .of .the .insert .and .it .is .crucial .for .the .functioning .of .the .woodburning .insert . .
The .chimney .draft .provides .a .partial .vacuum .in .the .insert . .This .vacuum .removes .the .smoke .from .the .
insert, .sucks .air .through .the .dampers .for .the .so-called .glass .pane .rinse .which .keeps .the .glass .free .of .soot, .
and .sucks .in .air .through .both .primary .and .secondary .dampers .for .the .combustion .
The .chimney .draft .is .created .by .the .differences .in .temperature .inside .and .outside .the .chimney . .The .
higher .the .temperature .within .the .chimney, .the .better .the .draft . .It .is .crucial, .therefore, .that .the .chimney .
is .warmed .through .properly .before .closing .the .damper .and .limiting .the .combustion .in .the .insert .(a .brick .
chimney .takes .longer .to .warm .through .than .a .steel .chimney) .
On .days .where .the .weather .and .wind .conditions .create .insufficient .draught .inside .the .chimney, .it .is .even .
more .important .to .warm .up .the .chimney .as .quickly .as .possible . .The .trick .is .to .quickly .get .some .flames .
going . .Split .the .wood .into .extra .fine .pieces, .use .an .extra .firelighter, .etc .
.
If .the .stove .has .not .been .used .for .a .longer .period, .it .is .important .to .check .that .the .chimney .pipe .is .not .