57
o
peratIonal
proBleMs
Blackened glass
• . The .wood .is .too .damp . .Only .use .wood .stored .for .at .least .12 .months .under .cover .and .with .a .moisture .
level .not .exceeding .20% .
• . The .doors .seals .may .be .not .be .tight .
• . Insufficient .secondary .air .introduced .to .the .pane-flushing .system . .Push .the .adjustment .bar .further .to .
the .right .until .the .glass .is .burned .clean . . .
• . Intermittent .firing . .Allow .the .insert .to .heat .through .properly .
Smoke in the room when opening door
• . The .damper .in .the .chimney .may .be .closed . .Open .the .damper .
• . Insufficient .chimney .draft . .See .section .on .chimney .or .contact .chimney .sweep .
• . Soot .door .leaking .or .dislodged . .Replace .or .refit .
• . Never .open .door .when .there .are .still .flames .in .the .wood .
Uncontrollable combustion
• . A .seal .in .the .door .is .not .completely .tight . .Replace .the .seal .
• . If .the .draught .is .too .strong .inside .the .chimney, .it .may .be .necessary .to .set .the .adjustment .bar .to .mini-
mum, .i .e . .to .the .left . .
If problems occur that you cannot fix yourself, please consult your wood-burning stove
dealer.