background image

Page 8 of 20 pages

Built-in example

Built-in example

C

C

 Min. 400 

 Min. 1750 

 Min. 350 

 Min. 491 

Convection opening

min. 563 cm²

Convection opening 

min. 375 cm²

Hollow spaces must not be filled 

with insulating materials

25 mm insulated

chimney

50 mm insulated 

chimney

Ceiling

Floor

Page 1 of 2

CAD-0193004

-

IHS Bagud

Sheet1

30-01-2020 nis

Frigivet 

x

nis

03-02-2020

Comment

Init.

Date

Rev.

Frigivet

nis

11-03-2020

nis

16-12-2019

3611844.15

1:15

A3

CAD-0190810

Com-Released

Created date:

Format:

Item number:

kg.

Part:

Weight:

Tolerance:

HWAM A/S

Nydamsvej 53-55

DK - 8362 Hørning

Tel. (+45) 86 92 18 33

Fax (+45) 86 92 22 18

Material:

Created by:

Configuration name:

Item:

Status:

Scale:

Drawing number:

Model:

 3 

C

C

 Min. 147 

 Min. 300 

 Min. 1750 

 Min. 350 

SECTION C-C

Convection opening 

min. 500 cm²

Convection opening

min. 750 cm²

Ceiling

Floor

25 mm insulated 

chimney

50 mm insulated 

chimney

Hollow spaces must not be filled 

with insulating materials

E

E

 Min. 700 

 Min. 50 

 Min. 50 

 Min. 185* 

 Min. 335* 

 Min. 1200 

 Min. 188 

 Min. 934 

SECTION E-E

Distance from furniture to glass pane

Combustible material

Fire wall - min. 50 mm Calcium Silicate

Insulated chimney

Page 1 of 1

UK - Hwam I40-55 sikkerhedsafstande røgudgang op

-

Side

Sheet1

27-05-2019 nis

Frigivet

Frigivet

nis

27-05-2019

Comment

Init.

Date

Rev.

Frigivet

nis

10-10-2019

nis

27-05-2019

3891.81

1:15

A3

CAD-0190810

Com-Released

Created date:

Format:

Item number:

kg.

Part:

Weight:

Tolerance:

HWAM A/S

Nydamsvej 53-55

DK - 8362 Hørning

Tel. (+45) 86 92 18 33

Fax (+45) 86 92 22 18

Material:

Created by:

Configuration name:

Item:

Status:

Scale:

Drawing number:

Model:

Summary of Contents for I 40/55

Page 1: ...Installation instructions EN I 40 55 20 10 2021 97 9696 www hwam com ...

Page 2: ......

Page 3: ...pe plate and serial number 6 Floor plate 6 Requirements for chimney and flue duct 6 INSTALLATION AND CONNECTION 6 In general 6 Installation in rooms with non combustible material 6 Installation in rooms with combustible material 6 Built in example 7 Installation instructions 10 Product information EcoDesign 18 ...

Page 4: ...y be bought separately Before installing the insert make sure that the floor can carry the insert the chimney and any other parts required for the installation Remember to consider that the stove must be connected to power Please be aware that not all glass parts are heat resistant For this reason a glass wall should sometimes be treated as a flammable wall in which case we ask you to contact your...

Page 5: ...744 396 543 306 266 290 Page 1 of 2 CAD 0193030 Created nis 18 12 2019 01 Comment Init Date Rev Frigivet nis 18 12 2019 A nis 18 12 2019 DS EN 22768 m 1 10 A4 ased Created date Item number kg Tolerance HWAM A S Nydamsvej 53 55 DK 8362 Hørning Tel 45 86 92 18 33 Fax 45 86 92 22 18 Created by Configuration name Item Drawing number Model Hwam I 40 55 IHS målskitse firkant mm A Min 70 Min 140 Min 295 ...

Page 6: ...ible material If the insert is installed in rooms where there is no combustible material we recommend a distance between masonry and the outer casing of 5 mm as a minimum This should prevent the brickwork from cracking when the outer casing expands during use The masonry above the casing must therefore be load bearing Installation in rooms with combustible material If the insert is installed adjac...

Page 7: ...350 SECTION C C Convection opening min 500 cm Floor SECTION E E Distance from furniture to glass pane Combustible material Fire wall min 50 mm Calcium Silicate Insulated chimney UK Hwam I40 55 sikkerh Sheet1 A 27 05 2019 nis Frigivet Frigivet nis 27 05 2019 B Comm Init Date Rev Frigivet nis 10 10 2019 C nis 27 05 2019 3891 81 1 15 A3 CAD 0190810 Com Released Created date Format kg Part Weight Tole...

Page 8: ...in 500 cm Floor SECTION E E Distance from furniture to glass pane Combustible material Fire wall min 50 mm Calcium Silicate Insulated chimney UK Hwam I40 55 sikkerh Sheet1 A 27 05 2019 nis Frigivet Frigivet nis 27 05 2019 B Comm Init Date Rev Frigivet nis 10 10 2019 C nis 27 05 2019 3891 81 1 15 A3 CAD 0190810 Com Released Created date Format kg Part Weight Tolerance HWAM A S Nydamsvej 53 55 DK 83...

Page 9: ...mbustible material Fire wall min 50 mm Calcium Silicate Insulated chimney UK Hwam I40 55 sikkerh Sheet1 A 27 05 2019 nis Frigivet Frigivet nis 27 05 2019 B Comm Init Date Rev Frigivet nis 10 10 2019 C nis 27 05 2019 3891 81 1 15 A3 CAD 0190810 Com Released Created date Format kg Part Weight Tolerance HWAM A S Nydamsvej 53 55 DK 8362 Hørning Tel 45 86 92 18 33 Fax 45 86 92 22 18 Material Created by...

Page 10: ...the installation of fans and fresh air system must have been completed Polystyrene from packaging may be placed on the floor and serve as protection for the insert when it is lifted out of the casing Note It isVERY important to secure the outer casing to the support with screws Otherwise it may fall out during servicing when the insert is turned out of the casing 1 2 3 4 ...

Page 11: ...Page 11 of 20 pages 5 6 7 ...

Page 12: ...Page 12 of 20 pages 8 9 10 ...

Page 13: ...Page 13 of 20 pages 13 12 11 ...

Page 14: ...Page 14 of 20 pages 16 15 14 ...

Page 15: ...Page 15 of 20 pages 19 18 17 ...

Page 16: ...Page 16 of 20 pages 21 22 20 ...

Page 17: ...Page 17 of 20 pages 24 25 23 ...

Page 18: ...ems in a way that is as sustainable as possible and that is in line with the current environmental protection reprocessing recycling and disposal technology Useful efficiency at nominal heat output 83 Energy efficiency index 110 Energy efficiency class A Electric power consumption nominal heat output kW 0 015 Electric power consumption minimum heat output kW 0 012 Electric power consumption standb...

Page 19: ...Page 19 of 20 pages ...

Page 20: ......

Reviews: