8
HWAM Monet connected with a solar collector system
Pump
Expansion
tank
Hot water
tank
Electric stick
Woodburing
stove circuit
220V
Outlet
Radiator circuit
F1
220V
DT
Expansion
tank
M1
F3
Mix 50°
1.
2.
Floor heating
Pump
F2
T
Fresh water supply
Solar collector
circuit
DT: Differential thermostat
M1: AT Mix-ventil
T: Thermostat KP 77
Floor heating
circuit
Connection with geothermal energy system
HWAM Monet is connected normally to the central heating system between the supply
and the return conduit so that some of the hot supply water is heated further, before it is
mixed with the cold return water. As the hot return water is not good for the heat pump, it is
necessary to insert a thermostat and a three-way valve, so the hot return water circulates
around the pump.
Function
When heated in the stove, the sensor of the thermostat registers rising temperature in the
return conduit, and the three-way valve will close the water around the heat pump and di-
rectly to the supply conduit. Therefore the heat pump will not register any consumption and
will automatically declutch. When the stove burns out, the temperature in the return conduit
will fall, and the three-way valve will once again let the cold water into the heat pump.
HWAM Monet connected with geothermal heat system
Earth conductor
Heat pump
M
Motor valve
Thermostate
Supply
conduit
Sensor
Return
conduit
Expansion
tank
Admission
AVTA-valve
Radiator
Pump
1. Thermal drain security
2. Safety valve
Drain
Outlet
Sensor
Hot service
water
Bypass