9
A. Supply conduit
B. Return conduit
C. E.g. AVTA valve 50 - 90°.
C. Will open at rising
C. temperature
D. Automatic aeration
E. Thermometer
Connection with automatically functioning AVTA valve
The connection secures together with correct firing the optimal utilization of the water kettle
of the stove. By using a Danfoss AVTA valve 50-90°C, you can secure an outlet tempera-
ture from the stove’s water tank of 70-75°C, and in this way avoid condensed water at the
water tank. At the same time a better secondary combustion is secured, as the fire is not
cooled too much down.
The AVTA valve is mounted at the pipe to the inlet socket piece of the stove (1) and with
the sensor through a 1” cross into to water tank of the stove through the out socket piece
(2). The valve is to be mounted in accordance with the instructions of the factory.
If the outlet pipe and the security conduit go downwards, there should always be mounted
an automatically aeration at the outlet pipe. Like that air pockets are avoided that could
arise by overheating in the lighting stage. If the connection is carried upwards from the
stove, a drain cock should be mounted at the inlet socket piece.
F. Manometer, if any
G. Admission with cold
water (domestic water)
H. Thermal circuit breaker
with sensor in connect-
ing branch (5). Opens at
90°C.
I. Safety valve
J. Outlet of the cooking coil
K. Outlet
1. Inlet 3/4" socket piece
2. Outlet 1" socket piece
3. Admission of cooking
water
4. Outlet of cooling water
5. Sensing socket