Title
Rev.
Page
HPP-240
Ver1.0
P.12
2-5-1) Manual Configuration
1) Run the printer in initial configuration mode.
※How to run in Initial Configuration Mode
When you turn the printer
’
s power on while pressing down on the FEED button for
more than 2 seconds, the PE LED and ERROR LED will simultaneously turn on / flash
and run the initial configuration mode. (9600 BPS, PARITY NONE, HARDWARE
HANDSHAKE)
2)After running the initial configuration mode, it will print as the following
.
[Menu]
1.Baud rate
2.Parity
3.Flow control
4.Hex Dump Mode
5.Print Density
6.Auto Melody
7.Cut Mode
8.Auto Buzzer
9.Print Speed
Select and then Enter...
Enter : Press the feed button once for
more than 1second.
Select: Press the feed button many times
less than 1second as menu number.
Exit : Turn power off then on.
Press the FEED button more than 1 seconds to confirm (Enter) less than 1 seconds to
select menu. For example, if you
’
d like to change the Auto Melody option in the list
number 6, press the FEED button less than 1 seconds 6 times, and more than 1 seconds
1 time. When terminating the configuration, just turn off and back on.
3)Continuing from the previous, you can confirm after selecting the category on the
printed list
.
Ex) [Baud rate]
-> 1.9600
2.19200
3.38400
4.115200
-> : Indicate current set status
Select and then Enter...
Meaning,
(->) indicates the current setting. When changing the settings, select from the
list and if you want to move to the next menu without making any changes, then just