21
Installation
1. Installation method
This welding machine use 50A electric leak protection switch, fuse capacity 40A.
Make sure the distribution switch is off before install the machine. Don’t install
the machine when hand is wet, don't put items on the welding cable, follow the
steps below:
Connect the machine input cable stably with the electric socket. The required
input voltage must be AC220Vm input cable must be ≥6mm
2
. The yellow and
green cable must be connect stably with the lead cable.
Connect the welding cable and lead cable into the plug, turn clockwise until
fixed well.
All the welding copper cable should be ≥16mm
2
.
When the welding cable length more than 20m, the square meter of the cable
should enlarge.
Installation and Operation