CYLINDER CONNECTION DIAGRAM
DUAL CYLINDER ROOM EXTENSIONS
ROD END
HIGH PRESSURE
HOSE CONNECTION
CAP END
HOSE CONNECTION
HOSE CONNECTION AT REAR OF
ROOM EXTENSION TUBE
VIEW 1
SYNCHRONIZING CYLINDER
HYDRAULIC CYLINDER
HYDRAULIC CYLINDER
STEEL TUBE
ROD END
CAP END
ROD END
CAP END
STEEL TUBE
HIGH
PRESSURE HOSE (B1)
HIGH PRESSURE HOSE (B1)
VIEW 1
DUAL CYLINDER ROOM EXTENSION
(A1)
(A1)
CAP END
CONNECTION - A
ROD END
CONNECTION - B
IMPORTANT: THE LINES (A1) BETWEEN THE CAP END OF THE HYDRAULIC CYLINDERS AND THE TEE
MUST BE THE SAME LENGTH AND DIAMETER.
THE LINES (B1) BETWEEN THE ROD END OF THE HYDRAULIC CYLINDERS AND THE SYNCHRONIZING
CYLINDER MUST BE THE SAME LENGTH AND DIAMETER. THE B1 LINES MUST BE HIGH PRESSURE HOSE.
(WITH SYNCRONIZING CYLINDER)
NOTE: THESE CONNECTIONS ARE
THE SAME FOR EACH ROOM EXTENSION
WITH DUAL ROOM CYLINDERS AND
SYNCHRONIZING CYLINDER. NOT ALL
TEE
1/8" OR 3/16" HOSE BEING REPLACED MUST MATCH THE ORIGINAL HOSE. ALL HWH 1/4" HOSE IS THE SAME.
DIFFERENT TYPES OF HOSE, ESPECIALLY HIGH PRESSURE HOSE, HAS BEEN USED. THE PRINTING ON A
NOTE:
STEEL TUBE.
DUAL CYLINDERS USE THE
ROOM EXTENSIONS WITH
27SEP04
MP65.3225
CYLINDER EXTEND - ROOM EXTEND
CYLINDER RETRACT - ROOM RETRACT
MP65.7021
CHECK OIL WITH ROOM RETRACTED